the blinking of the bar graph stops, when the PO2 is below 0.5 bar

audible alarms are given and the actual PO2 value blinks when it exceeds the preset limit

in dive planning the maximum depth according to the O2% and maximum PO2 selected.

6.4.TECHNICAL SPECIFICATION

Dimensions and weight:

Vytec:

 

 

Diameter:

61mm [2.4in].

Thickness:

28mm [1.1in].

Weight:

68g [2.4 oz].

Transmitter:

Max. diameter: 40 mm [1.57 in].

Length:

80mm [3.15 in].

Weight:

118g [4.16 oz].

Rated working pressure: 300 bar [4000 psi], maximum allowed pressure 360 bar [5000 psi].

Display resolution:1 bar [1 psi].

Depth Gauge:

Temperature compensated pressure sensor.

Salt water calibrated, in fresh water the readings are about 3% smaller (calibrated complying with prEN 13319).

Maximum depth of operation: 80 m [262 ft] (complying with prEN 13319).

Accuracy: ± 1% of full scale or better from 0 to 80 m [262 ft] at 20°C [68°F] (complying with prEN 13319).

Depth display range: 0 … 150 m [492 ft].

Resolution: 0.1 m from 0 to 100 m [1 ft from 0 to 328 ft].

Temperature display:

 

Resolution:

1°C [1.5°F].

Display range: -9 ... +50°C [-9 ... +122°F].

Accuracy:

± 2°C [± 3.6°F] within 20 minutes of

 

 

temperature change.

Calendar Clock:

 

Accuracy:

± 25 s/month (at 20°C [68°F]).

12/24 h display.

68

Page 70
Image 70
Suunto VYTEC DS manual Technical Specification, Transmitter