Model 5454 Operating Procedures
Priming
Step 1
Sanitize the mix tank, mix tank cover, mix probe and
funnel. Place the mix tank and cover in the m ix cabinet.
Step 2
Insert the mix probe prongs inside the mix tank, and
connect the mix probe to the socket receptacle.
Figure 46
Step 3
Place the free end of the suction line in the mix tank.
Figure 47
Step 4
Install the funnel. Fill the tank with FRESH m ixand
close the mix cabinet door.
Figure 48
Note: Use only FRESH mix when priming the
freezer.
Step 5
Place an empty mix pail beneath the door spouts and
open the draw valves. With the prime plug still in the
UP position, press the PUMP keypad. This will allow
themix to be pumped t hrough the freezing cylinder and
force out any remaining sanitizing solution. When f ull
strength mix is flowing from the doorspout s, close the
draw valves.
Figure 49