40
TroubleshootingGuide Model 5454
PROBLEM PROBABLE CAUSE REMEDY PA GE
REF.
4. The mix c abinet
temperature is too
warm.
a. Warm mix was placed in the
cabinet.
a. Mix placed in the mix tank
should be below 40_F
(4.4_C).
--
b. The softech control needs t o
be adjusted.
b. Call a service technician to
adjust the softech control.
--
c. The mix cabinet door was left
open.
c. The door must be kept closed. 28
d. The mix cabinet door gasket
is not sealing.
d. Repair or replace the door
gasket.
--
e. The condenser on air cooled
units is dirty.
e. Clean condensers regularly. 37
5. The mix c abinet
temperature is too
cold.
a. The softech control needs t o
be adjusted.
a. Call a service technician to
adjust the softech control.
--
6. Syrup is bleeding int o
the freezing cylinder.
a. The spinner shaft was
improperly installed.
a. The spinner blade must be
flush with the bottom of the
door spout.
20
b. The center o- ring on the draw
valve was improperly
lubricated or worn.
b. Lubricate the o- ring properly,
or replace every 3 months.
44
c. The draw handle is not
completely closed.
c. Push the draw handle up
completely.
--
7. Product is c ollecting
on top of the draw
valve.
a. There is inadequate
lubrication on the spinner
shaft.
a. Lubricate the spinner shaft
properly.
20
8. Product is c ollecting
on top of the freezer
door.
a. The top o- ring on the draw
valve is improperly lubricated
or worn.
a. Lubricate properly or replace
every 3 months.
44
9. There is excessive
mix leakage from the
bottom of the door
spout.
a. There is a worn, missing, or
incorrect o-ring on the draw
valve.
a. Replace rubber parts every 3
months. Check the o- ring
size.
44
b. There is improper lubrication
on the draw valve o- rings.
b. Lubricate the o- rings properly. 19
c. There is inadequate
lubrication on the spinner
shaft.
c. Lubricate the spinner shaft
properly.
20