TroubleshootingGuide Model 5454
PROBLEM PROBABLE CAUSE REMEDY PA GE
REF.
14. Large pressure
adjustments are
needed to calibrate
the syrups or unable
to get adequate syrup
delivery with syrup
sampler.
a. There is hardened syrup in
the syrup lines.
a. Clean and sanitize the syrup
lines weekly.
35
b. The syrup and air lines are not
matched.
b. Match the color spiral air and
syrup line to the correct syrup
tank.
28
c. There is a plugged restrictor in
the vanilla or strawberry syrup
line connection.
c. Clean the restrictor.Remove
the air line from the syrup
tank. Remove the syrup line
(vanilla or strawberry) from
the syrup tank. Disassemble
the syrup quick disconnect.
Pull the restrictor out and
clean.
--
d. The syrup line fitting is
plugged at the freezer door
connection.
d. Clean the syrup line fitting. 16
15. The pump will not
operate.
a. The pump motor may be off
on reset.
a. Push the reset button on t he
pump motor.
--
16. The machine will not
run while in AUTO.
a. The machine is unplugged. a. Plug the machine into the wall
receptacle.
--
b. The circuit breaker is off, or
thefuseisblown.
b. Turn the breaker on, or
replace the fuse.
--
c. The machine is low on mix.
The MIX OUT light is on.
c. Add mix to the mix tank. --
d. The mix probe is not installed
properly.
d. Check the mix probe
installation.
27
e. The beater motor is out on
reset.
e. Reset the freezer. 14