Part No. TEL–09949, Rev A

Pre-Installation Information and Activities

June 2001

Page 26 of 34

Preparing the 9110 DMS for 326X Series Card Modems

When managing 326X Series Modems in an enclosure using the 9110 Dial Management System (DMS), set the Use option (in the 9110 Comm Port Definition screen) to Complete. This configures the 9110 to poll all modems (see “Polling” in Chapter 1 of the 9110 DMS User's Guide) even if one modem is not responding.

Change the Use option to Complete as follows:

1)Shut down the 9110.

2)Start up the Setup Program, log on, and select the Setup File Editor Option.

3)Open SETUP.WIN from the File menu.

4)Select Edit from the Comm menu. The Comm Port List Window is displayed.

5)Select a Comm port that is cabled to a 326X Series modem enclosure.

6)Select the Use option and select Complete in the popup window. Ensure the setting next to Use changes to Complete.

7)Press F1 to save the change in memory.

8)Repeat Steps 4 through 7 for each Comm port cabled to a 326X Series modem enclosure.

9)Select Save from the File menu and save SETUP.WIN.

10)Exit the Setup Program and restart the 9110.

326X Modem Card Power Supply Requirements in 21-Card Enclosure

If you are using more than nine 326X cards in a Modular Nest 21 enclosure, you must have two power supplies. A third power supply can be added for redundancy.