Texas Instruments TLV1562 manual Software Overview, Initialize SPI, Save, Pull Down CSTART

Models: TLV1562

1 99
Download 99 pages 55.38 Kb
Page 37
Image 37
Initialize SPI

Software Overview

1

 

 

 

 

 

 

 

 

 

 

 

Start

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

Initialize DSP

 

 

 

 

 

 

 

 

Wait States, AR Pointer, IRQ Table, Data Memory, Serial Port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H/L Transition on INTO ?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Initialize SPI

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

Active Transmitter, Use Frame Sync,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Generate External Clock

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAVE_

INTO

_MEMORY = 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INTO (External Interrupt)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Save Modified Register of

 

 

 

 

 

SAVE_INTO_MEMORY = 0

 

Initialize DSP Memory For Sample Store

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AR7 Points to The First Store Location

 

 

 

The IRQ Routine, if Not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AR0 Points to The Table End

 

 

Automatically Saved by The

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADCOUNT = Table Size (Number of Samples)

 

 

 

 

DSP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Not Required)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IME CALABRATION = 1

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IME CALABRATION = 0

 

 

 

 

 

Calibrate Internal Midscale Error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SME CALABRATION = 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calibrate System Midscale Error

 

 

 

 

 

IME CALABRATION = 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Initialize (Id) The Two ADC Registers

CR0 = CR0_SEND

CR1 = CR1_SEND

Start Sampling

Pull Down CSTART

Wait 100 ns

Stop Sampling and Start Conversion

Reset CSTART (Set Back High)

INTO_DRINEN = 1

POLLING_DRIVEN =

NO_INTO_SIGNAL =

 

 

1

1

 

Main Program

Wait Until End of Conversion

Wait Until End of Conversion

 

Stay in Idle Mode

Poll INTO Pin Until h/0 Transition Occurs

Wait For a Certain Time

 

1

 

 

 

INTO

 

 

 

 

2

 

 

 

Start New Sampling

 

 

 

Pull Down CSTART

 

 

 

Read Sample

 

 

 

Stop Sampling and Start Conversion

 

 

 

Reset CSTART (Set Back High)

SAVE_INTO_MEMORY = 0

 

SEND_OUT_PARALLEL = 1

 

Store Sample Into Memory

 

 

 

 

Copy Last Sample to Parallel DAC

SEND_OUT_PARALLEL = 1

Save Sample to AR7 – Pointed Location

 

 

 

Start New Conversion

Table End Reached?

No

 

 

 

 

(AR7 = AR0 ?)

 

SEND_OUT_SERIAL = 1

 

 

 

Copy Last Sample to Serial DAC

 

Yes

 

SEND_OUT_SERIAL = 0

Reset Actual Memory Pointer

 

if Send Register is Empty

 

 

 

 

 

AR& = First Memory Store Location

 

 

SAVE_INTO_MEMORY = 0

 

 

Figure 7. Flow Chart Mono Interrupt Driven Mode Using CSTART to Start Conversion

Interfacing the TLV1562 Parallel ADC to the TMS320C54x DSP

31

Page 37
Image 37
Texas Instruments Software Overview, Interfacing the TLV1562 Parallel ADC to the TMS320C54x DSP, Initialize SPI, Save