Program Files:

Software Overview

Program Files:

MONOIDM1.ASM

includes the complete software algorithm to control the monomode

CONSTANT.ASM

common file of all modes (constants definition)

VECTORS.ASM

common file of all modes (IRQ vector table)

Other Files:

 

linker.cmd

organization of the DSP memory (data and program memory)

auto.bat

batch file to start the compiler for the monomode software

asm500.exe

C54x Code compiler

lnk500.exe

C54x linker

The timing requirements to interface the ’C54x to the ADC are provided in Tables 6 and 7. The STEP numbers given there can be found again as Marker in the code. This helps to debug and verify the code.

Code verification:

To verify the software, the user must change the code in the MONIDM1.ASM file and save those changes. The next step is to recompile the three .ASM files by executing the AUTO.BAT batch file. If compiler and linker finish without error messages, the new output file is ready to load in the DSP program memory (e.g. with the GoDSP development tools) and to execute.

The flow chart in Figure 7 gives a general overview of the software structure (MONOIDM1.ASM).

28SLAA040

Page 34
Image 34
Texas Instruments TLV1562 Program Files, Other Files, Code verification, common file of all modes constants definition