Clear (CLR) memory preset

From this submenu, up to three saved presets for the currently selected input can be cleared from memory.

1. Using either the Adjust horizontal ([) or Adjust vertical ({) knob, select (< >) either N/A, 1, 2, or 3 to select a preset. The default is <N/A>.

2. To clear the preset, press the Next button.

NClearing a preset by pressing the Next button will also cause a return to the Memory Preset menu.

To exit the Clear memory preset function without clearing a preset, press Menu.

Recalling a preset

Recalling a saved preset requires that the desired input be currently selected and that the input button be pressed successively to activate each saved preset (up to three). Each saved preset will display the message “Input #X Memory Y”, where “X” refers to the input (1 to 4) and “Y” refers to the preset (1 to 3).

In the absence of any saved presets, the “Input #X Memory Y” message will not be displayed for those presets.

NThe presets are specific to a selected output rate. If the output rate is subsequently changed, the previously saved preset will have no effect on the video output. However, if the original output rate is later restored for a saved preset, the preset will re-apply to that output rate.

Input preset

Input preset saves current values for parameters such as input type, color, tint, contrast, brightness, detail, aspect ratio, horizontal start, vertical start, horizontal active, vertical active, phase, total pixels, horizontal position, vertical position, horizontal size, vertical size, zoom, and OSD text.

IP configuration

The IP Configuration menu displays the IP address of the unit, the Subnet mask, and Gateway IP address.

MEMORY PRESETS

MENU

IP

CONFIG

NEXT

 

 

I 196.168

 

 

 

P 254.254

 

 

 

 

 

 

 

 

 

 

View IP address of the unit.

NEXT

S255.255 M 000.000

View the subnet mask of the unit.

NEXT

 

 

G 000.000

 

NEXT

 

 

M 000.000

 

 

 

 

 

 

 

 

 

 

 

 

View gateway IP address of the unit.

Figure 2-16— IP Configuration menu

To change an IP address, do the following:

1.Press and hold the Input 4 and Next buttons simultaneously for 2 seconds. This introduces the Setup mode.

2.Change the flashing octet selection by using the Adjust vertical ({) knob. Change the selection numbers by using Adjust horizontal ([) knob.

3.Press the Menu button to return to the IP address setup and the Next button to select another address setup.

4.Press the Menu button to save and exit.

The IP configuration menu “times out” if there is no activity for over 10 seconds.

DVS 304 • Installation and Operation 2-17

Page 29
Image 29
Extron electronic DVS 304 D, DVS 304 AD manual Input preset, IP configuration, Clear CLR memory preset, Recalling a preset