Extron electronic DVS 304 AD manual Serial Communication, cont’d, 3-20DVS 304 Serial Communication

Models: DVS 304 DVS 304 A DVS 304 D DVS 304 AD

1 96
Download 96 pages 15.78 Kb
Page 60
Image 60
3-20 DVS 304 • Serial Communication

3-20 DVS 304 • Serial Communication

Command/response table for IP control port commands (continued)

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to processor)

(host to processor)

(processor to host)

 

IP setup commands, continued

Set subnet mask24

E X1(CS}

WX1(CS

Ips•X1( ]

X1( is the subnet mask (xxx.xxx.xxx.xxx).

 

 

 

 

Syntax is the same as for the IP addresses

 

 

 

 

Leading zeros are optional in setting values.

Read subnet mask

ECS} E

WCS

X1( ]

Leading zeros are suppressed.

Set gateway IP address24

E X1$CG}

W X1$CG

Ipg•X1$ ]

X1$ is IP address. Leading zeros are optional

Read gateway IP address

ECG}

WCG

X1$ ]

 

Set broadcast mode

E X6$X1$EB}

W X6$%2C X1$EB

BmdX6$, X1$ ]

 

Set administrator password 24

E X3#CA}

WX3#CA

Ipa•X3# ]

Set the administrator access password

 

 

 

 

(X3# is 4-12 alphanumeric characters)

 

 

 

 

The password is case sensitive. Special

 

 

 

 

characters (spaces or symbols) are

 

 

 

 

not allowed.

Clear administrator

E•CA}

W%20CA

Ipa• ]

Clear/remove all passwords

password 24

 

 

 

(administrator and user)

NA user password cannot be assigned if an administrator password does not exist. Entering a password when the DVS 304 has not been configured yields an E14 response from the processor. If the administrator password is cleared (removed), the user password is also removed.

Read administrator password

ECA}

WCA

X3# ]

 

Set user password14 24

E X3#CU}

WX3#CU

Ipu•X3# ]

Set the user access password

 

 

 

 

(X3# is 4-12 alphanumeric characters)

 

 

 

 

The password is case sensitive. Special

 

 

 

 

characters (spaces or symbols) are

 

 

 

 

not allowed.

NA user password cannot be assigned if an administrator password does not exist.

Clear user password24

E•CU}

W%20CU

Ipu•]

This clears the user password only

Read user password24

ECU}

WCU

X3#]

 

NX1$ = IP address (xxx.xxx.xxx.xxx); leading zeros in each of 4 fields are optional in setting values, and are suppressed in returned values.

X1( = Subnet mask (xxx.xxx.xxx.xxx). Leading zeros are optional in setting values in each of four fields, and are suppressed in returned values. X3# = Password (12 characters = maximum length; no special characters are allowed).

X6$ = Broadcast repetition rate in seconds (0 – 255 max; default = 0 = clear). The response is returned with leading zeros. 1 – 11 = entry without password goes to the level pecified (if an admin password exists). The response as returned

as 2-digits with a leading zero.

Serial Communication, cont’d

Page 60
Image 60
Extron electronic DVS 304 AD Serial Communication, cont’d, 3-20DVS 304 Serial Communication, IP setup commands, continued