Serial Communication, cont’d

Command/response table for SIS commands (continued)

Command

ASCII Command

Response

Additional description

 

(host to scaler)

(scaler to host)

 

 

 

 

 

Contrast

 

 

 

Specific value

X8% ^

Con X8% ]

Increment up

+ ^

Con X8% ]

Increment down

– ^

Con X8% ]

View

^

X8% ]

Brightness

Sets contrast level to X8%. Increments contrast level. Decrements contrast level. View current setting.

Specific value

X8% Y

Brt X8% ]

Increment up

+ Y

Brt X8% ]

Increment down

– Y

Brt X8% ]

View

Y

X8% ]

Detail Filter

Sets brightness level to X8%. Increments brightness level. Decrements brightness level. View current setting.

Set detail level

X8% D

Shp X8% ]

Increment up

+ D

Shp X8% ]

Increment down

– D

Shp X8% ]

View detail value

D

X8% ]

Horizontal Shift

Specify the detail level to X8%. Increase the detail level. Decrease the detail level. Show the detail setting.

Specific value

X8^H

Hph X8% ]

Increment up

+ H

Hph X8% ]

Increment down

– H

Hph X8% ]

View

H

X8% ]

Vertical Shift

Set horizontal centering to X8%. Shift window right.

Shift window left.

Horizontal centering value is X8%.

Specific value

X8^ /

Vph X8^ ]

Increment up

+ /

Vph X8^ ]

Increment down

– /

Vph X8^ ]

View

/

X8^ ]

Horizontal Size

Set vertical centering to X8^. Shift window down.

Shift window up.

Vertical centering value is X8^.

Specific value

X8& :

Hsz X8& ]

Increase Size

+:

Hsz X8& ]

Decrease Size

–:

Hsz X8& ]

View

:

X8& ]

Vertical Size

Set horizontal sizing to X8&. Widen the window.

Make the window narrower. Horizontal sizing value is X8&.

Specific value

X8& ;

Vsz X8& ]

Increase Size

+;

Vsz X8& ]

Decrease Size

–;

Vsz X8& ]

View

;

X8& ]

Set vertical sizing to X8&. Make the window taller. Make the window shorter. Vertical sizing value is X8&.

NX8% = Picture adjustment: X8^ = H and V position X8& = H and V size

X8* = Zoom

0 to 127

Values depend on current output rate Values depend on current output rate 100 to 200%

3-10 DVS 304 • Serial Communication

Page 50
Image 50
Extron electronic DVS 304 AD, DVS 304 D manual Command/response table for SIS commands