Extron electronic DVS 304 AD, DVS 304 D manual Reference Material, cont’d, General

Models: DVS 304 DVS 304 A DVS 304 D DVS 304 AD

1 96
Download 96 pages 15.78 Kb
Page 90
Image 90
Reference Material, cont’d

Reference Material, cont’d

Contact closure

9-pin female D connector (same as RS-232 connector)

Contact closure pin configurations.

See pins 1, 4, 5, 6, and 7 above

IR controller module

Extron IR 901 (optional)

Program control

Extron’s control/configuration program for Windows®

 

Extron’s Simple Instruction Set (SIS) Microsoft® Internet Explorer, Telnet

General

Power

100VAC to 240VAC, 50/60 Hz, 30 watts, internal, autoswitchable

Temperature/humidity

Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing

 

Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing

Cooling:

 

DVS 304, DVS 304D

Convection, vented on sides and top

DVS 304A, DVS 304AD ....

Convection, vented on sides

Mounting

 

Rack mount

DVS 304, DVS 304D .. Yes, with optional 1U, 9.5" deep rack shelf (RSU 129, #60-190-01; RSB 129, #60-604-01)

DVS 304A, DVS 304AD Yes, with included brackets Furniture mount

DVS 304, DVS 304D .. Yes, with optional MBU 125 Under-desk Mounting Kit, #70-077-01; or MBD

 

129 Through-desk Mounting kit, #70-077-02

Enclosure type

Metal

Enclosure dimensions

 

DVS 304, DVS 304D

1.75" H x 8.75" W x 10.5" D (1U high, half rack wide)

 

4.4 cm H x 22.2 cm W x 26.7 cm D

 

(Depth excludes connectors and knobs.)

DVS 304A, DVS 304AD ....

1.75" H x 17.5" W x 10.5" D (1U high, full rack wide)

 

4.4 cm H x 44.4 cm W x 26.7 cm D

 

(Depth excludes connectors and knobs. Width excludes rack ears.)

Product weight

 

DVS 304, DVS 304D

3.3 lbs (1.5 kg)

DVS 304A

6.5 lbs (2.9 kg)

DVS 304AD

6.8 lbs (3.1 kg)

Shipping weight

 

DVS 304, DVS 304D

6 lbs (3 kg)

DVS 304A, DVS 304AD ....

11 lbs (5 kg)

DIM weight

 

DVS 304, DVS 304D

12 lbs (6 kg)

Vibration

ISTA 1A in carton (International Safe Transit Association)

Regulatory compliance

 

Safety

CE, C-tick, CUL, UL

EMI/EMC

CE, C-tick, FCC Class A, ICES, VCCI

MTBF

30,000 hours

Warranty

3 years parts and labor

NAll nominal levels are at ±10%.

NSpecifications are subject to change without notice.