Extron electronic DVS 304 A manual Serial Communication, cont’d, Command, ASCII Telnet, Response

Models: DVS 304 DVS 304 A DVS 304 D DVS 304 AD

1 96
Download 96 pages 15.78 Kb
Page 58
Image 58
Manual background

3-18 DVS 304 • Serial Communication

Command/response table for IP control port commands (continued)

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to processor)

(host to processor)

(processor to host)

 

Web browser specific

Read response from last URL

E UB }

WUB

Response from

 

cmd

 

 

command ]

 

IP setup commands

 

 

 

 

Set unit name24

E X1@ CN }

WX1@ CN

Ipn • X1@]

Change the processor’s name to one of your

 

 

 

 

choosing

 

 

 

 

(X1@). The name consists of up to 24 alphanu

 

 

 

 

meric

 

 

 

 

characters (and the minus The first character

 

 

 

 

must be a letter, the last character cannot be a

 

 

 

 

minus

 

 

 

 

sign (hyphen). Case does not matter.

Set unit name to factory

E • CN }

W%20CN

Ipn •X4( ]

X4( is the name the processor was shipped

default24

 

 

 

with:

 

 

 

 

DVS304-##-##-##, a combination of the model

 

 

 

 

name

 

 

 

 

and the last 3 pairs of the hex numbers in the

 

 

 

 

processor’s

 

 

 

 

MAC address (e.g., DVS304-00-02-3d).

Read unit name

E CN }

WCN

X1@ ]

X1@ is the processor’s current unit name.

Set time/date24

E X1#CT }

W X1# CT

Ipt • X1# ]

X1# is local date and time format. The set

 

 

 

 

format is MM/DD/YY-HH:MM:SS.

 

 

 

 

Example: 11/18/03-10:54:00

Read time/date

E CT }

WCT

X1# ]

The Read format is day of week DD month year

 

 

 

 

HH:MM:SS.

 

 

 

 

Example: Tue, 18 Nov 2008 18:19:33

N X1@ = Name is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9), and the minus sign/hyphen (-). The first character must be an alpha character. The last character must not be a minus. No blank or space characters are permitted, and no distinction is made between upper and lowercase.

X1# = Local date and time format Set format (MM/DD/YY-HH:MM:SS); e.g., 06/21/02-10:54:00 Read format (day of week, date month year (HH:MM:SS), e.g., Thu, 20 Feb 2003 18:19:33

X4( = Default name: a combination of the model name and the last 3 character pairs of the unit’s MAC address (e.g., DVS-304-00-023D)