Thermador P30 and 36 Ranges Figures 6 and, Important Installation Information

Models: P30

1 44
Download 44 pages 15.31 Kb
Page 14
Image 14
30" and 36" Ranges (Figures 6 and 7)

Step 4: Installing Anti-Tip Device

30" and 36" Ranges (Figures 6 and 7)

Thermador Service Part No.

Qty.

Description

415078

4

Screw, Phillips, #10 x 1-1/2"

600413

1

Anti-Tip Bracket, Floor-Mounted

IMPORTANT INSTALLATION INFORMATION:

The anti-tip bracket may be attached to a solid wood cabinet having a minimum wall thickness of 3/4".

The thickness of the wall or floor may require use of longer screws, available at your local hardware store.

In all cases, at least two (2) of the bracket mount- ing screws must be fastened to solid wood or metal.

Use appropriate anchors when fastening the mounting bracket to any material other than hard- wood or metal.

Prepare holes at fastener locations as identified below:

FIG. 6 - Mounting Anti-tip Bracket

-For walls, wall studs, or floors composed of solid wood or metal, drill 1/8" pilot holes.

-For walls or floors composed of drywall, sheet-rock or other soft materials, drill 3/16" holes to a minimum depth of 1-3/4", then tap plastic anchors into each of the holes using a hammer.

-For walls or floors composed of concrete or concrete block, drill 3/16" holes to a mini- mum depth of 1-3/4", then tap concrete anchors into each of the holes using a hammer.

-For walls or floors having ceramic tile cover- ing, drill 3/16" holes through the tile only, then drill into the material behind the tile as indi- cated immediately above.

If the range is moved to a new location, the Anti- Tip Device must be removed and reinstalled.

MOUNTING ANTI-TIP BRACKET

The alternative floor mounted bracket shall be installed as follows:

a)Place bracket on floor in position shown in Figure 7 (Bracket may be used in either corner of the installation area).

b)Secure to floor or wall stud.

c)Later, when the unit is installed, the adjustable leg will slide under the bracket.

FIG. 7

2-1/2"

from edge of range

2-1/2" (typical -

either side)