Thermador PD30, PD36, PD48 installation instructions Wire Lead Connection, Wire Connection

Models: PD30, PD36, PD48

1 48
Download 48 pages 52.14 Kb
Page 18
Image 18
3-WIRE LEAD CONNECTION

Step 6: Electrical Requirements, Connection & Grounding

A3- or 4-conductor supply may be connected to the terminal block.

3-WIRE LEAD CONNECTION

1.Remove upper nuts only from the terminal block studs. Do not remove nuts which secure range internal wiring leads.

2.Secure the neutral, grounded wire of the supply circuit, to the center stud of the terminal block with nut. (See Fig. 10).

3.Secure the L1 (black) and L2 (red) power leads to the outside terminal block studs (brass colored) with nuts.

4.Tighten nuts securely.

4-WIRE CONNECTION

1.Remove upper nuts only from the terminal block studs. Do not remove lower nuts which se- cure range internal wiring leads.

2.Remove ground strap screw and bend the strap up as shown in Fig. 11.

3.Secure the neutral wire to the center stud of the terminal block with nut.

4.Secure the L1 (black) and L2 (red) power leads to the outside terminal studs (brass colored) with nuts.

5.Secure the bare copper ground lead to the range chassis using the ground screw previously used for the ground strap. Be sure that neutral and ground terminals do not touch.

6.Tighten all connections securely.

FIG. 9 Conductor Securement

 

Upper Nut

 

Cupped Washer

Supply Wire

 

Flat Washer

FIG. 10 3 Wire Connection

 

L2 Red

 

Neutral White

 

L1 Black

FIG.11 Ground Strap

Bend Ground Strap Up

FIG. 12 Secure Neutral Wire

 

L1 Black

L2 Red

 

 

 

Ground Wire

15

Page 18
Image 18
Thermador PD30, PD36, PD48 Wire Lead Connection, Wire Connection, Electrical Requirements, Connection & Grounding