5. LOADING THE MEDIA
5- 6
3. When performing a media calibration from your host computer, pull out the media through the
Media Outlet, not through the Peel-off Unit. If a calibration is performed with the media set
through the Peel-off Unit, multiple labels will be peeled at the same time, and stick on the printer.
After the completion of the calibration, ensure that the distance between the media outlet and
the leading edge of the media is 15 cm or over. If it is less than 15 cm, repeat the calibration
until the distance becomes 15 cm or over. (Use this procedure particularly if the media length
is short.)
Precautions
When performing the “media calibrat ion” from your host computer, ensure that the “peel”
checkbox in the “Options” tab in the printer driver is unchecked.
If the “peel” checkbox is checked, peeling will fail. Consequently, the media calibration will not
be performed successfully.
15 cm or over