5. LOADING THE MEDIA
5- 3
[Supplemental Remarks]
When using an inside wound media with the
Peel-off Unit, do not use the Media Roll Damper.
Draw the media underneath the Media Roll
Damper and the Media Roll Guide.
9. Adjust the Media Guide to the width of the media.
[Supplemental Remarks]
Make sure that the print side faces upward.
Fit the Media Guide to the media edges.
Failure to do this may cause a misalignment of
print position or ribbon wrinkles.
10. Set the Print Head Pressure Selection Lever in accordance with the width of the loaded media.
Media width
(mm) Print head
pressure Marking on
the lever
15 to 30 Low I
30 to 60 Medium II
60 to 120 High III
Print Head Pressure Selection Leve
r
High pressure
Low pressure