(1. 3. 3) Changing each setting in PW SNR mode

Move up down

Set by pushing

By pushing

DATA UP, DOWN

MENU UP, DOWN

 

-- SHUTTER --

 

MODE

E.TRG

E.TRG

PW SNR

TRG.P

 

PART

OFF

<MODE = E.TRG E.TRG = PW SNR>

Sutter mode MANU, SS, E.TRG

E.TRG mode

1P SNR, 1P SR, PW SNR, PW SR, RR

Input trigger pulse setting at PW SNR and PW SR

Input trigger pulse : positive polarity

Input trigger pulse : negative polarity

Partial scanning switch OFF/120fps/180fps/E.120fps/E.180fps

(a) Changing the polarity of inputting trigger pulse setting

1Set the "" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.

2Select either , by pushing [DATA UP], [DATA DOWN] buttons.

(b) Changing the partial scanning setting

1Set the "" to PART by pushing [MENU UP], [MENU DOWN] buttons.

2Select either OFF/120fps/180fps/E.120fps/E.180fps by pushing [DATA UP], [DATA DOWN] buttons.

Note:

The longer the storage time with extended exposures, the more visible certain characteristics of CCD cameras become: fixed pattern noise, white pixels, etc.

16

Page 16
Image 16
Toshiba IK-TF5C instruction manual Changing each setting in PW SNR mode, Mode = E.TRG E.TRG = PW SNR