(1. 3) Changing each setting in E.TRG mode

The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR.

First set the "→ " to MODE and select E. TRG, then set the "→ " to E.TRG and select the desired E.TRG mode.

(1. 3. 1) Changing each setting in 1P SNR mode

Move up down By pushing

MENU UP, DOWN

Set by pushing

DATA UP, DOWN

-- SHUTTER --

 

 

 

 

MODE

E.TRG

E.TRG

1P SNR

TRG.P

 

 

 

 

 

 

 

 

EXP.

16ms

PART

OFF

<MODE = E.TRG E.TRG = 1P SNR>

Shutter mode MANU, SS, E.TRG

E.TRG mode

 

 

 

1P SNR, 1P SR, PW SNR, PW SR, RR

 

 

 

Input trigger pulse setting at 1P SNR and 1P SR

 

 

 

 

 

 

Input trigger pulse : positive polarity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input trigger pulse : negative polarity

 

 

 

 

 

 

Exposure time setting at 1P SNR and 1P SR

 

 

0.01 ms

 

0.02 ms

 

 

0.4 ms

 

 

1 ms

 

 

16 ms

 

 

 

 

 

 

 

 

 

 

 

 

0.01 ms

0.02 ms 0.1 ms

1 ms

 

 

 

 

 

 

step

 

step

step

step

• Partial scanning switch OFF/60fps/90fps

(a) Changing the polarity of inputting trigger pulse setting

1Set the "→ " to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.

2Select either , by pushing [DATA UP], [DATA DOWN] buttons.

(b) Changing 1P SNR exposure time setting

1Set the "→ " to EXP. by pushing [MENU UP], [MENU DOWN] buttons.

2Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.

Note:

The longer the storage time with extended exposures, the more visible certain characteristics of CCD cameras become: fixed pattern noise, white pixels, etc.

(c) Changing the partial scanning setting

1Set the "→ " to PART by pushing [MENU UP], [MENU DOWN] buttons.

2Select either OFF or 60fps, 90fps by pushing [DATA UP], [DATA DOWN] buttons.