5.CONNECTION

5.1 Standard Connection

Lens

IK-TF7

Less than 4 mm

Camera cable

 

(option)

RGB

DC IN 12V

Image processing

 

DC power supply

equipments, etc.

 

5. 2 Cautions on Connection

When connecting the camera cables, be sure to turn off the camera and the other equipment connected.

We suggest using a C mount lens made for a 3CCD camera.

When using another lens, the best camera performance of this camera may not be obtained.

(For example, low resolution may occur, focus may be lost through the range of a zoom lens, and flare, ghost or shading may occur)

Furthermore, in order to avoid damaging the mounting portion of the camera head, use a lens which has projection dimension from the mounting base of less than 0.157"(4mm).

For DC power supply connecting to DC IN 12V terminal, use UL listed and/or CSA approved ungrounding type AC adaptor with the specifications described below.

Power supply voltage

: DC12V± 10%

Current rating

: More than 830 mA

Ripple voltage

: Less than 50 mV(p–p)

Connector

: HR10A–7P–4S by HIROSE electronics Co. Ltd

 

Pins 1, 2

: 12V

 

Pins 3, 4

: GND

5. 3 Connector Pin Assignments

DC IN 12V

1+12V

2+12V

3GND

1 3

4

GND

2 4

8

RGB

1R

2G

3B

4TXD

5GND

6GND

7GND

8SYNC

912V

10GND

11RXD

12TRIG

13HD IN/OUT

14VD IN/OUT

15INDEX

5 4 3 2 1

10 9 8 7 6

15 14 13 12 11

IK-TF7(E)

Page 8

2004.03.24, 0:59 PMAdobe PageMaker 6.5J/PPC

Page 8
Image 8
Toshiba IK-TF7 instruction manual Standard Connection, Connector Pin Assignments