2TroubleshootingProcedures
Procedure1: Powerstatuscheck
Procedure2: Adaptor/batteryreplacement
Procedure3: Powersupplyconnectioncheck
Procedure4: Diagnosticcheck
Procedure5: Internalconnectioncheck
Procedure1 PowerStatusCheck
ThefollowingLEDSindicatethepowersupplystatus:
BatteryLED
DC-INLED
ThepowersupplycontrollerdisplaysthepowersupplystatusthroughtheBatteryandtheDC- INLEDSaslistedinthetablesbelow.
BatteryState | LEDcolors | Definition |
|
|
|
Charging | Amber,solidon | BatterychargingwithAC. |
|
|
|
| green,solidon | BatteryfullychargedbyAC |
|
|
|
| Ambercoloroff | BatteryabnormalstopchargingwithAC |
|
| (Badcell/Overheated) |
|
|
|
Discharging | Amber,blinking | Batterywithinlowstate:12minutes |
| (LED on for 1 second | remaining |
| every4seconds) |
|
|
|
|
| Amber,blinking | Batterywithincriticallowstate:3 |
| (LED on for 1 second | minutesremaining.Thesystemis |
| every2seconds) | |
| withouttheACpowerconnected. | |
|
| |
|
|
|
| Ambercoloroff | Batterynotinloworcriticallowstate; |
|
| It’sindischargingstate |
|
|
|
SATELLITEL500D/PROL500DMAINTENANCEMANUAL10