Toshiba MR-3018, MR-3022 service manual Description of Interface Signals

Models: MR-3018 MR-3022

1 122
Download 122 pages 40.04 Kb
Page 14
Image 14

2.6Description of Interface Signals

The following 6 lines are used to transmit/receive signals between the equipment and the RADF.

REQ

Communication request signal (from equipment to the RADF)

DF-REQ

Communication request signal (from the RADF to equipment)

DF-ACK

Communication request acknowledging signal (from the RADF to equipment)

ACK

Communication request acknowledging signal (from equipment to the RADF)

TxD

Data transmitted from equipment to the RADF

RxD

Data transmitted from the RADF to equipment

Data communication (RxD and TxD) between the scanner and the RADF has adopted the serial com- munication system which does not allow checking using testing devices to see whether the signals are transmitted/received properly in the field.

RADF

Equipment

REQ

DF-ACK

TxD

DF-REQ

ACK

RxD

Fig. 2-5

MR-3018/3020/3021/3022

© 2005 - 2011 TOSHIBA TEC CORPORATION All rights reserved

GENERAL DESCRIPTION

 

2 - 6

05/12

Page 14
Image 14
Toshiba MR-3018, MR-3022 service manual Description of Interface Signals