Toshiba MR-3022, MR-3018 service manual Adjustment of Horizontal Position, Checking

Models: MR-3018 MR-3022

1 122
Download 122 pages 40.04 Kb
Page 85
Image 85

5.5Adjustment of Horizontal Position

Note:

Check if the image adjustment for the equipment is performed properly before this adjustment of the RADF.

(See the Service Manual or Service Handbook of the applicable equipment.) Also, the RADF position and height shall be adjusted properly.

[A] Checking

Check the image using the chart (original) with a center line in the following procedure.

(1)Place the chart provided as an original with its face up on the original tray of the RADF.

(2)Press the [START] button.

(3)Fold the copy in half and check if the center line is misaligned.

[B]Adjustment

(1)Turn the power ON while pressing [0] and [5] simultaneously.

(2)Key in [358]*1 / [3043] *2 and then press the [START] button. *1 : For e-STUDIO352/353/452/453

e-STUDIO281c/351c/451c, e-STUDIO2500c/3500c/3510c, e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C, e-STUDIO202L/203L/232/233/282/283, e-STUDIO205L/255/305/355/455

*2 : For e-STUDIO2040C/2540C/3040C/3540C/4540C, e-STUDIO206L/256/306/356/456

If the center line of the copy image is shifted to the front side of the equipment, enter a value larger than the current one.

Note:

Changing one value shifts the copy image by 0.0423 mm.

G

Fig. 5-28

If the center line of the copy image is shifted to the rear side of the equipment, enter a value smaller than the current one.

5

© 2005 - 2011 TOSHIBA TEC CORPORATION All rights reserved

MR-3018/3020/3021/3022

 

ADJUSTMENT

5 - 15

11/12

Page 85
Image 85