(3)Open the RADF. Remove 2 screws, and then take off 2 holders and platen guide.

(4)Remove 2 screws. Open the post-reading lower guide and take off the post-reading upper guide.

Holder

Platen guide

Holder

Fig. 4-90

Post-reading

upper guide

Fig. 4-91

(5)Release 2 latches and take off the Original

exit/reverse sensor from the post-reading

upper guide.

Original exit/reverse sensor

 

Fig. 4-92