Troubleshooting and tips

7.6Incorrect date and time

ÊSet the date and time in the operating system or in the BIOS Setup under the Main menu, using System Date and System Time respectively.

INote that the operating system may affect the system time. For example, the operating system time may deviate from the system time under Linux, and would overwrite the system time in the default setting on shutdown.

If the date and time are still wrong after the server has been switched off and back on again, replace the lithium battery (for a description refer to the "System Board D3141 for PRIMERGY RX600 S6 Technical Manual") or contact our customer service team.

7.7Drives reported as "dead" when starting system

RAID controller configuration incorrect

ÊCheck and correct the settings for the drives using the RAID controller utility. Further information is provided in the manual for the RAID controller.

7.8Added drive reported as defective

RAID controller is not configured for this drive

The drive was probably installed when the system was switched off.

ÊReconfigure the RAID controller for the drive using the corresponding utility. Information is provided in the documentation for the RAID controller.

or

ÊRemove and reinstall the drive while the system is switched ON.

If the drive continues to be shown as defective, then replace it (see "Hot-plug HDD/SSD modules" on page 94).