1.5Technical data
Electrical data (hot-plug power supply unit)
Rated voltage range | 100 - 127 V / 200 - 240 V | ||
|
| ||
Frequency | 50 Hz - 60 Hz | ||
|
|
| |
Rated current (basic configuration) | 3.1 A (240 V) |
| |
|
|
| |
Max. rated current | 11 A (240 V) |
| |
|
|
| |
Active power min. (typical configuration) | 750 W |
| |
|
|
|
|
Active power max. (typical configuration) | 1800 | W |
|
|
|
| |
Rated active power max. | 2640 | W (11 A x 240 V) | |
|
|
|
|
Apparent power (typical configuration) | 1830 | VA |
|
|
|
|
|
Heat dissipation | 750 | W/h = | 2559 btu/h |
| 1950 | W/h = | 6654 btu/h |
| 3360 | W/h = 11465 btu/h | |
|
|
|
|
Main power fuse | 16 A |
|
|
|
|
|
|
Protection class | I |
|
|
|
|
|
|
22 | Operating Manual | RX600 S6 |