CSS components

8.1.5.1Identifying the defective memory

The faulty memory module can be identified from the corresponding DIMM Fault LED on the respective memory board (see figure 28) when the server is open.

ÊOpen the server (see "Opening the server" on page 125).

Figure 28: Button and indicators on memory board

1

ATTN button

4

Mirror LED (green)

2

ATTN LED (orange)

5

8x DIMM Fault LED (orange)

3Power LED (green)

ÊUse the DIMM Fault LEDs (5) to identify the faulty memory module.

The respective DIMM Fault LED lights up orange and indicates the slot on the memory board that is occupied by the faulty memory module.

ÊMake a note of which LED (e.g. "1B“) on which memory board is lit orange.

ÊPress the ATTN button (1) .

ÊWait until ATTN LED (2) and Power LED (3) are turned off.

ÊRemove the memory board as described in "Removing the memory board in question" on page 111

110

Operating Manual

RX600 S6

Page 110
Image 110
Fujitsu RX600 S6 manual CSS components Identifying the defective memory, Open the server see Opening the server on