Preface
Dimensions / Weight
Rack (W x D x H) | 482.6 mm (Bezel) / 444.8 mm (Body) x 765.0 mm x |
| 176.0 mm |
|
|
Mounting depth rack | 728 mm |
|
|
Height unit rack | 4 U |
|
|
19" rackmount | Yes |
|
|
Mounting cable depth | 100 mm (1000 mm rack recommended) |
rack |
|
|
|
Weight | minimum 32 kg; maximum 46 kg (actual weight may |
| vary depending on configuration) |
|
|
Rack integration kit | rack integration kit as option |
|
|
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Environment class 3K2 | EN 60721 / IEC 721 Part |
Environment class 2K2 | EN 60721 / IEC 721 Part |
|
|
Temperature: |
|
Operation (3K2) | 10°C - 35°C |
Transport (2K2) | |
|
|
Humidity | 10% - 85% (non condensing) |
|
|
Condensation during operation must be avoided!
Noise level
Sound power level LWAd (ISO 9296) | < 6.5 | B (standby) |
| < 6.6 | B (operation) |
|
| |
Sound pressure level at bystander position LpAm | < 50 dB(A) (standby) | |
(ISO 9296) (at < 23 °C) | < 50 dB(A) (operation) |
24 | Operating Manual | RX600 S6 |