Fujitsu RX600 S6 CSS components Replacing a defective fan, Unlocking a fan module and removing it

Models: RX600 S6

1 134
Download 134 pages 57.82 Kb
Page 92
Image 92

CSS components

8.1.2.1Replacing a defective fan

Figure 17: Unlocking a fan module and removing it

ÊPress the two green handles and lift the fan module out of the housing (see figure 17).

VCAUTION!

Never leave the fan module slot empty for more than two minutes during operation. Otherwise, excessive temperatures could damage system components.

ÊInsert the new fan module in the empty slot until it clicks into place. To make sure the fan has engaged press again.

The new fan module is tested by Server Management. The LED then either does not light at all (fan is ok) or lights up (fan is not ok).

ÊClose the server (see "Opening/Closing the server" on page 125).

92

Operating Manual

RX600 S6

Page 92
Image 92
Fujitsu RX600 S6 manual CSS components Replacing a defective fan, Unlocking a fan module and removing it