CSS components

ÊCarefully press the memory board into its slot (see figure 33 on page 114).

ÊPress both handles downwards (2) so that both green release tabs engage.

ÊPress the ATTN button.

ÊWait until the ATTN LED is turned off.

ÊClose the server as described in "Closing the server" on page 127.

8.1.5.6Adding a memory board

To add memory boards during operation, proceed as follows:

ÊOpen the server (see "Opening the server" on page 125).

ÊRemove the air baffle of the respective memory board slot.

Figure 33: Removing the memory air baffle to add a memory board

ÊPress on the top of the memory air baffle (1), move it in the direction of the arrow (2) and out of the housing.

IKeep the memory air baffle for future use.

ÊInstall the equipped memory board into the respective slot.

IMemory boards that you insert must suit the fitting rules and the appropriate configuration. See the "System Board D3141 for PRIMERGY RX600 S6 Technical Manual" for details.

114

Operating Manual

RX600 S6

Page 114
Image 114
Fujitsu RX600 S6 manual Adding a memory board, Removing the memory air baffle to add a memory board