Hardware installation
Installation requirements for AC non redundant configurations
For systems not requiring AC redundancy, the power supply subsystem can be installed with up to 4 PSUs. The PSUs can be connected to a single or multiple AC sources.
PSU Configuration | Max. DC Loading | DC Redundancy |
|
|
|
1+1 (2 PSUs) | 830W | Yes |
|
|
|
2+1 (3 PSUs) | 1580W | Yes |
|
|
|
3+1 (4 PSUs) | 2320W | Yes |
|
|
|
Table 3: Maximum DC Loading Requirements
Three power supply modules are capable of handling the maximum power requirements for a fully configured PRIMERGY RX600 S6 server system, which include the following:
●Four processors
●1024 GB of memory
●Eleven PCIe
●Eight hard disk drives and/or solid state disks
●One optical drive
●One tape drive
The hot swap feature allows the user to replace a failed power supply module without affecting the system functionality.
50 | Operating Manual | RX600 S6 |