Check code

 

Check code name

Possible causes

 

 

 

 

 

[P12]

 

Malfunction of I/U fan motor

A Failure of fan motor connector

(New code)

 

 

 

B Failure of fan motor

 

 

 

 

C Failure of I/U board

 

 

 

 

D Failure of cross flow fan shaft

 

 

 

 

 

 

 

 

 

 

 

 

 

When AC cord is plugged

 

P. C. board

 

 

in, I/U fan starts rotating.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check the fan motor output DC voltage on the I/U board.

Check voltage on the motor

 

connector CN210 pin C (GND,

 

 

(Blue)

 

 

 

 

 

 

black) and

pin E (+V line,

 

yellow) while fan is rotating.

Yellow

(Yellow)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(White)

 

1.0VDC or

 

 

Below 1.0VDC

 

 

(Black)

 

higher

 

 

Black

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Failure of I/U

 

 

 

Failure of I/U fan

 

 

 

(Red)

 

 

 

 

 

 

 

 

MCC-1510 board

 

 

 

motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 