Check code | Check code name | Possible causes |
|
|
|
[E02] | R/C transmission error | Signal transmission to indoor unit is |
(New code) |
| disabled. |
|
|
|
* Not indicated on the central controller and outdoor unit
Com. cable between | NO | Correct communication cable. | |
R/C and I/U connected |
|
| |
|
|
| |
properly? |
|
|
|
|
|
| |
YES |
|
|
|
|
|
|
|
Failure of R/C |
|
|
|
transmitter → Replace R/C. |
|
|
|
|
|
|
|
Check code | Check code name | Possible causes |
|
|
|
[E03] | I/U - R/C communication error | No communication from R/C and communication adapter. |
(New code) | (detected by I/U) |
|
|
|
|
Indoor unit (I/U) detects this error when it cannot receive signals from remote controller (R/C).
Check communication wiring of R/C A and B.
This code E03 is not displayed on the R/C because of communication error.
This code is displayed on the
– 38 –