Tests and Diagnostics
3-66 [CONFIDENTIAL] TECRA S3 Maintenance Manual (960-532)
4. DUMP program
(a) When DUMP is selected, the following message appears.
DIAGNOSTICS-HARD DISK & FLOPPY DISK DUMP : VX.XX
Drive type select (1:FDD, 2:HDD) ?
(b) Select a drive type. If 2:HDD is selected, the display will go to step (h).
If 1:FDD is selected, the following message will appear.
Select drive number (1:A, 2:B) ?
(c) Select a drive number and the following message will be displayed.
Format type select (1:2DD, 3:2HD) ?
(d) If 3:2HD is selected, the following message will appear. Select a media mode.
2HD media mode (1:1.20MB, 2:1.44MB, 3:1.23MB)?
(e) The following message will appear.
Insert source disk into drive A:
Press any key when ready.
(f) Insert a source disk and press any key and the following message will appear.
—— Max. address ——
[Track ] = XXXX
[Head ] = XX
[Sector] = XX
Track number ????
(g) Set the track number, head number and sector number you want to dump. The
system will access the disk and dump a list. Then the message shown in (k)
will appear.
(h) The following message will appear when selecting 2:HDD in (a).
Select drive number (1:C, 2:D) ?
(i) Select a drive number and the following message will be displayed.
---Max. address ---
[LBA ] = XXXXXXXXX
LBA number ????????
(j) Set the LBA number you want to dump. The system will access the disk and
dump a list.