2 Troubleshooting Procedures
2-8 [CONFIDENTIAL] TECRA S3 Maintenance Manual (960-532)
Procedure 2 Error Code Check
If the power supply microprocessor detects a malfunction, the DC IN icon blinks orang e. Th e
blink pattern indicates an error as shown below.
Start Off for 2 seconds
Error code (8 bit)
“1” On for one second
0 On for half second
Interval between data bits Off for half second
The error code begins with LSB (Least Significant bit).
Example: Error code 11h (Error codes are given in hexadecimal format.)
Check 1 Convert the DC IN icon blink pattern into the hexadecimal error code and
compare it to th e tables below. Then go to Check 2.
Table 2-3 Error code
Error code Whe re E rr o r occ urs
1*h DC IN (AC Adapter)
2*h 1st batter y
3*h 2nd battery
4*h S3V output
5*h E5V output
6*h E3C output
7*h 1R5-E1V output (CH0)
8*h 1R8-B1V output
9*h PPV output
A*h PTV output (CH0)
B*h 1R5-E1V output (CH1)
C*h PGV output
D*h VG1R8-P1V output
E*h PTV output (CH1)
F*h -
Formatted: Indent: Left: 17.85 pt,
Hanging: 17.85 pt, Numbered +
Level: 1 + Numbering Style: Bullet +
Start at: 1 + Alignment: Left + Aligned
at: 18 pt + Tab after: 0 pt + Indent at:
36 pt, Tabs: 18 pt, Left
Formatted: Numbered + Level: 1 +
Numbering Style: Bullet + Start at: 1 +
Alignment: Left + Aligned at: 18 pt +
Tab after: 0 pt + Indent at: 36 pt,
Tabs: 18 pt, Left