10. Stick the protection cover G (B), protection cover SC (A) and two fixing tapes (C)
and (D).
(A)
(B)
(C)
(D)
0 to 1
0 to 1
Fit the cover according to
the outline of the screw.
0 to 1 mm
Do not make the tape over the top of the module.
The tape MUST NOT appear o n the display.
Stick the tape according to the outline of the LCD module. Make
sure the tape does not appear o n the side of the module.
Figure 4-87 Replacing Sharp fluorescent lamp (XGA) (23)
TECRA S3 Maintenance Manual (960-532) [CONFIDENTIAL] 4-105