2 Troubleshooting Procedures
TECRA S3 Maintenance Manual (960-532) [CONFIDENTIAL] 2-17
Check 3 The IRT checks the sy st e m board. When the IRT de t ect s an er ror, the sy stem
stops or an error message appears.
If one of the following error messages (1) through (17), (22) or (23) is displayed,
go to Procedure 4.
If error message (18) is displayed, go to the Keyboa rd/Touch pad Troubles hooting
Procedures in Section 2.7.
If error message (19), (20) or (21) is displayed, go to the 2.5” HDD
Troubleshooting Procedures in Section 2.6.
(1) PIT ERROR
(2) MEMORY REFRESH ERROR
(3) TIMER CH.2 OUT ERROR
(4) CMOS CHECKSUM ERROR
(5) CMOS BAD BATTERY ERROR
(6) FIRST 64KB MEMORY ERROR
(7) FIRST 64KB MEMORY PARITY ERROR
(8) VRAM ERROR
(9) SYSTEM MEMORY ERROR
(10) SYSTEM MEMORY PARITY ERROR
(11) EXTENDED MEMORY ERROR
(12) EXTENDED MEMORY PARITY ERROR
(13) DMA PAGE REGISTER ERROR
(14) DMAC #1 ERROR
(15) DMAC #2 ERROR
(16) PIC #1 ERROR
(17) PIC #2 ERROR
(18) KBC ERROR
(19) HDC ERROR
(20) Built-in HDD ERROR
(21) Select Bay ERROR
(22) TIMER INTERRUPT ERROR
(23) RTC UPDATE ERROR
Formatted: Indent: Left: 53.85
pt, Hanging: 22.7 pt, Numbered
+ Level: 1 + Numbering Style: 1,
2, 3, … + Start at: 1 + Alignment:
Left + Aligned at: 18 pt + Tab
after: 43.2 pt + Indent at: 43.2
pt, Tabs: 18 pt, Left