Manuals
/
Trane
/
Household Appliance
/
Air Conditioner
Trane
PTAC-SVX01C-EN manual
Models:
PTAC-SVX01C-EN
1
51
52
52
Download
52 pages
2.5 Kb
45
46
47
48
49
50
51
52
<
>
Troubleshooting
Install
Wiring Diagram
Component Replacement
Warranty
Dimension
Maintenance
Power receptacle configurations
Wiring Voltage
Indoor Fan Cycle set up
Page 51
Image 51
Page 50
Page 52
Page 51
Image 51
Page 50
Page 52
Contents
September
Installation Operation, and Maintenance
Packaged Terminal Air Conditioner
PTAC-SVX01C-EN
Table
Table of Contents
Warranty
Operation
4 5 6
Model Number Description
Outdoor coil Rotary compressor Power cord
P T E E 0 9 0 1 * A A
WARNING Hazardous Voltage with Capacitators
General Information
NOTICE
Important Environmental Concerns
Service Equipment and Procedures
Refrigerant Handling Procedures
Recover and Recycle Refrigerants
Refrigerant Handling and Safety
Fire Hazard
Pre-Installation
Pre-Installation Considerations
Checklist
Shipping Package
Pre-Installation
Receiving Checklist
Receiving and Handling
Unit Dimensions
Figure
Wall Sleeve
Air discharge
Unit Dimensions
Front View
PTAC Wall Sleeve Unit controls
Fire Hazard
Installation
Live Electrical Components
Electrical Requirements
Table
Installation
Power receptacle configurations
Table
panel from wall sleeve
Installation Procedure
Step 1. Remove rear closure
Hazardous Voltage w
5.Install unit chassis in wall sleeve
Step 2. Install drain kit in wall sleeve
Step 4. Install wall sleeve in wall opening
Step 3. Install outdoor air grille in wall sleeve
Installation
Step 7. Install the unit controls
Table
Installation
Wiring Voltage
Wiring Voltage
Indoor Temperature setpoint
Step 8. Configure the display module settings
Field commissioning support
Installation
Installation
Step 9. Programmable Settings
3.Temperature Setpoint Limiting set up
Installation
Operation without configuration
2.Indoor Fan Cycle set up
Occupied state
Energy Management System
Installation
Occupancy States
PTAC-SVX01C-EN
Installation
Table 14. PTEE manual test sequence
Table 15. PTHE manual test sequence
Automatic 3-minute Compressor Lockout
Door Switch Occupancy Sensor
Operation
Sequence of Operation
Air Discharge Grille
Operation
Remote Fan Operation
Vent Control
Table 17. Air conditioner performance data
Operation
Operation
Table 18. Heat pump performance
PTAC-SVX01C-EN
Table
Cooling temperature change - heat pumps
Cooling temperature change - air conditioners
Operation
PTAC-SVX01C-EN
Operation
Table 21. Cooling amperage — air conditioners
Table 22. Cooling amperage — heat pumps
Operation
Table
Heat pump reverse cycle heating capacity
PTAC-SVX01C-EN
Table 25. Unit accessory model numbers
Table 25. Unit accessory model numbers
Operation
Table 26. Hydronic heat options
Accessory Type
Power Voltage
Operation
Chassis
Maintenance
Maintenance Procedures
Hazardous Voltage
Ensure Terminal Cover is in Place
Maintenance
Refrigeration System Service
Scheduled Maintenance
Use of Pressure Regulator – Valves – Gauges
Maintenance Brazing
Leak Testing
High Temperatures
Maintenance
Evacuation Procedure
Evacuation
Fan Motor Overheat
Line Piercing Valves
Charging Procedure
Charging the System
Refrigerant
Cooling Performance Test
Cooling Performance Test
Thermometers
Sling Psychrometer
WARNING Hazardous Voltage w/Capacitors
Heating Power Consumption Test
Calculating procedure
Testing Capacitor Resistance
Outdoor Coil and Air Thermistors
Ground Test
Resistance Test
Indoor Coil and Air Thermistors
Table 27. Thermistor indoor coil
Maintenance
Table 27. Thermistor indoor coil
Table 27. Thermistor indoor coil
Power cord Installation
Power Cord Removal
Component Replacement
Unit Disassembly Procedures
Maintenance
Control Board Replacement Procedure
Indoor Fan and Motor
Outdoor Fan and Motor
Resetting Diagnostics
Troubleshooting
Diagnostics
Translating Multiple Diagnostics
Troubleshooting
Table 31. Compressor output does not energize
Table 33. Outdoor fan output does not energize
Table 36. Ventilation output does not energize
Troubleshooting
Random restart timer
Table 35. Auxiliary heat output does not energize
Table 39. Control fuse is blown
Troubleshooting
Table 38. Output on when the mode is off
Table 37. Condensate pump does not energize
Wiring Diagram
Wiring Diagram
1For 265 VAC unit, connect P8 and P9
Wiring Diagram
Wiring Diagram
+ _ + _
Wiring Diagram
Figure 34. 3rd party class 2 thermostat wiring
Figure 35. Remote display wiring
Warranty
Warranty
Full 1st Year Warranty
Full 2nd - 5th Sealed System Warranty
Page
09/06
Literature Order Number
PTAC-SVX01C-EN
Date