Trane PTAC-SVX01C-EN manual Operation, Cooling amperage — air conditioners

Models: PTAC-SVX01C-EN

1 52
Download 52 pages 2.5 Kb
Page 26
Image 26
Table 21. Cooling amperage — air conditioners

Operation

Table 20. Cooling temperature change - heat pumps (continued)

 

 

PTHE0701

PTHE0702

PTHE0901

PTHE0902

PTHE1201 PTHE1202

PTHE1501

PTHE1502

Room

 

Temperature across

Temperature

Temperature across

Temperature across

 

indoor coil (T)

acrossndoor coil (T)

indoor coil (T)

indoor coil (T)

airdry

Room air wet

 

 

 

 

 

 

 

 

bulb

bulb

Min

Max

Min

Max

Min

Max

Min

Max

 

 

 

 

 

 

 

 

 

 

 

70

12

16

13

16

11

15

10

14

 

 

 

 

 

 

 

 

 

 

75

65

18

22

18

21

16

20

16

19

 

 

 

 

 

 

 

 

 

 

60

24

28

23

26

21

25

21

24

 

 

 

 

 

 

 

 

 

 

 

55

31

34

29

31

26

30

26

29

 

 

 

 

 

 

 

 

 

 

 

65

12

15

12

15

10

13

9

13

 

 

 

 

 

 

 

 

 

 

70

60

17

20

16

18

14

17

13

17

 

 

 

 

 

 

 

 

 

 

55

22

24

20

22

18

21

18

21

 

 

 

 

 

 

 

 

 

 

Table 21. Cooling amperage — air conditioners

Condenser

PTEE0701

PTEE0702

PTEE0901

PTEE0902

PTEE1201

PTEE1202

PTEE1501

PTEE1502

inlet air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temp.

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.6

2.9

2.4

2.4

3.6

3.9

3.2

3.2

4.8

5.2

4.2

4.2

6.5

7.1

5.7

5.7

100

2.6

2.9

2.4

2.6

3.4

4.0

2.9

3.1

5.6

5.6

3.9

4.3

6.6

8.0

5.6

6.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

95

2.4

2.8

2.3

2.5

3.2

3.8

2.7

3.0

5.4

5.3

3.7

4.1

6.2

7.6

5.3

5.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

2.3

2.7

2.2

2.4

3.1

3.6

2.6

2.9

5.2

5.1

3.6

3.9

5.9

7.2

5.1

5.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

2.2

2.6

2.1

2.3

2.9

3.4

2.5

2.7

4.9

4.8

3.4

3.8

5.6

6.8

4.8

5.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

2.1

2.4

2.0

2.2

2.8

3.3

2.3

2.6

4.7

4.6

3.2

3.6

5.3

6.4

4.6

5.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 22. Cooling amperage — heat pumps

Condenser

PTHE0701

PTHE0702

PTHE0901

PTHE0902

PTHE1201

PTHE1202

PTHE1501

PTHE1502

inlet air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temp.

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.6

2.9

2.4

2.4

3.6

3.9

3.2

3.2

4.8

5.2

4.2

4.2

6.5

7.1

6.3

6.3

100

2.6

2.9

2.5

2.7

3.4

4.0

3.0

3.2

5.6

5.5

4.1

4.5

6.6

8.0

5.5

6.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

95

2.4

2.8

2.4

2.6

3.2

3.8

2.8

3.1

5.3

5.2

3.9

4.3

6.2

7.6

5.2

5.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

2.3

2.6

2.2

2.5

3.1

3.6

2.7

3.0

5.0

5.0

3.7

4.1

5.9

7.2

5.0

5.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

2.1

2.5

2.1

2.3

3.1

3.4

2.6

2.9

4.8

4.7

3.5

3.9

5.6

6.8

4.7

5.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

2.1

2.3

2.1

2.2

2.9

3.3

2.5

2.7

4.6

4.5

3.3

3.7

5.3

6.4

4.5

4.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes: Shaded area is rating ampere

26

PTAC-SVX01C-EN

Page 26
Image 26
Trane PTAC-SVX01C-EN manual Operation, Cooling amperage — air conditioners, Cooling amperage — heat pumps