Pre-Installation

Table 2. Minimum clearances and projections

Option

In.

Mm

In.

Mm

In.

Mm

 

 

 

 

 

 

 

Minimum clearances

 

Minimum projection

 

 

 

 

 

 

 

 

A

 

B

 

 

C

 

 

 

 

 

 

 

Wall sleeve only

3

75

0

0

0

0

 

 

 

 

 

 

 

Subbase kit

3

75

3 1/4

85

2 3/4

70

 

 

 

 

 

 

 

Leveling legs kit

3

75

3

75

2

50

 

 

 

 

 

 

 

Hydronic heat kit(1)

9

230

2-6”(2)

50 -150(3)

3-3 1/8(4)

76-80(5)

Drain kit

3

75

0(6)

1(7)

0

0

Hardwire kit

3

75

3

75

0

0

(1)Max height is based on skirt options available.

(2)This dimension can be from 2-6", but if this dimension exceeds 6" an extended standard kick plate is necessary.

(3)This dimension can be from 50-150mm, but if this dimension exceeds 150mm an extended standard kick plate is necessary.

(4)To achieve a flush fit between the hydronic front and the finished wall, dimension "C" must be between 3" and 3-1/8". If this dimension is more than 3-1/8" there will be a gap between the front and the wall. This gap could permit occupant access to hydronic lines or other dangerous parts.

(5)To achieve a flush fit between the hydronic front and the finished wall, dimension "C" must be between 76-80mm. If this dimension is more than 80mm there will be a gap between the front and the wall. This gap could permit occupant access to hydronic lines or other dangerous parts.

(6)If inside mounted then B = 1-1/2 inches

(7)If inside mounted then B = 40 mm

Receiving and Handling

Shipping Package

The chassis and the cabinet front ship in one carton. Accessories ship separate.

Receiving Checklist

Complete the following checklist immediately after receiving unit shipment to detect possible shipping damage.

Verify that the unit nameplate data corresponds to the sales order and bill of lading (including electrical data).

Visually inspect the unit exterior for physical signs of shipping damage or material shortages.

If a unit appears damaged, inspect it immediately before accepting the shipment. Remove access panels and check for interior component damage. Make specific notations concerning the damage on the freight bill. Do not accept delivery.

Report concealed damage to the freight line within the allotted time after delivery. Verify with the carrier what their allotted time is to submit a claim.

Note: Failure to follow these procedures may result in no reimbursement for damages from the freight company.

Do not move damaged material from the receiving location. It is the receiver’s responsibility to provide reasonable evidence that concealed damage did not occur after delivery.

Do not continue unpacking the shipment if it appears damaged. Retain all packaging. Take photos of damaged material if possible.

Notify the carrier’s terminal of the damage immediately by phone and mail. Request an immediate joint inspection of the damage by the carrier and consignee.

Notify your HVAC representative of the damage and arrange for repair. Have the carrier inspect the damage before making any repairs to the unit.

PTAC-SVX01C-EN

7

Page 7
Image 7
Trane PTAC-SVX01C-EN manual Pre-Installation, Receiving and Handling, Shipping Package, Receiving Checklist

PTAC-SVX01C-EN specifications

The Trane PTAC-SVX01C-EN is a cutting-edge Packaged Terminal Air Conditioner (PTAC) designed to provide optimal temperature control, energy efficiency, and user comfort in a variety of settings, including hotels, apartments, and office buildings. This unit stands out with its robust features and advanced technologies, making it a reliable choice for meeting diverse heating and cooling needs.

At the heart of the Trane PTAC-SVX01C-EN is its innovative design, which combines powerful performance with quiet operation. This unit utilizes a high-efficiency compressor that ensures rapid cooling and heating, providing ideal comfort regardless of the external climate. With a capacity range suitable for smaller spaces, the PTAC delivers strong performance while maintaining energy efficiency, thus reducing operational costs over time.

One of the key characteristics of the PTAC-SVX01C-EN is its user-friendly interface. The intuitive controls allow users to effortlessly adjust temperature settings, fan speeds, and modes of operation, including cooling, heating, and fan only. This flexibility enhances user comfort while optimizing energy consumption. Additionally, the unit features a programmable timer, enabling users to schedule operation according to their specific needs, further conserving energy when spaces are unoccupied.

The unit's Quiet Operation Technology minimizes noise levels, making it an ideal choice for environments where peace and quiet are paramount. This feature is particularly beneficial in hospitality settings, where guests expect a tranquil atmosphere. The PTAC is engineered to provide ample airflow while minimizing sound, creating a pleasant indoor environment.

Another standout feature of the Trane PTAC-SVX01C-EN is its advanced air filtration system. The integrated filter effectively captures dust, allergens, and other airborne particles, promoting a cleaner and healthier living environment. This is particularly essential for individuals with allergy sensitivities or respiratory issues.

Durability is also a hallmark of the PTAC-SVX01C-EN. Built with high-quality materials, it is designed to withstand the demands of continuous operation while requiring minimal maintenance. The unit's sleek and compact design allows for easy installation in various locations, ensuring versatility without sacrificing performance.

In summary, the Trane PTAC-SVX01C-EN represents a perfect blend of efficiency, comfort, and innovative technology. Its user-friendly controls, quiet operation, and advanced air filtration make it a leading choice for those seeking reliable climate control solutions in residential and commercial spaces alike. Whether for heating or cooling, the Trane PTAC-SVX01C-EN is engineered to deliver exceptional performance and lasting dependability.