TS8G~16GCF600

600X CompactFlash Card

 

 

 

￿Signal Interface

Electrical specifications shall be maintained to ensure data reliability. Additional requirements are necessary for Advanced Timing Modes and Ultra DMA modes operations. See next sections for additional information.

Item

Signal

Card10

 

 

 

 

 

 

 

 

Host10

 

-CE1

Pull-up to VCC 500 K

 

R

 

50 K

and

 

 

 

 

 

 

 

 

-CE2

 

 

 

 

 

 

 

 

 

 

shall be sufficient to keep inputs inactive

 

 

 

 

 

 

 

Control Signal

-REG

 

 

 

 

 

 

 

when the pins are not connected at the

 

 

 

 

 

 

 

 

-HIOE

 

 

 

 

 

 

 

 

host.1

 

 

 

 

 

 

 

 

 

 

 

 

 

-IOWR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-OE

Pull-up to VCC 500 K

 

R

50 K

.1,2

 

 

 

 

 

 

 

 

-WE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RESET

Pull-up to VCC 500 K

 

R

 

50 K .

1,2,9,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READY

 

Ω ≧

 

Ω

 

 

 

 

 

 

 

.3

Status Signal

-WAIT

 

 

 

Pull-up to VCC R

10 K

 

WP

 

 

 

 

 

 

 

 

 

 

 

 

 

Ω ≧

 

Ω

 

In PCMCIA PC Card modes Pull-up to VCC

 

 

 

 

 

R

 

10 K

.4

 

 

 

 

 

 

 

 

In True IDE mode, if DMA operation is

 

 

 

 

 

supported by the host, Pull-down to Gnd R

 

 

Ω ≧

 

Ω

 

 

 

 

 

 

5.6 K

.5

 

 

 

 

-INPACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PC Card / True IDE hosts switch the pull-up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to pull down in True

IDE

Ωmode if DMA

 

 

 

 

 

 

 

 

operation is supported.

 

 

 

 

 

 

 

 

 

The PC Card mode Pull-up may be left

 

 

 

 

 

 

 

 

active during True IDE mode if True IDE

 

 

 

 

 

 

 

 

 

 

Ω

 

 

 

 

 

 

 

 

 

 

 

DMA operation is not supported.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Address

A[10:00]

 

 

 

 

 

 

 

 

 

 

 

 

 

-CSEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data Bus

D[15:00]

 

 

 

 

 

 

1.

 

Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

Card Detect

-CD[2:1]

Connected to GND in the card

 

 

 

 

 

 

 

 

Voltage Sense

-VS1

 

 

 

 

 

 

Pull-up to Vcc 10 K

 

R 100K .

-VS2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery/Detect

BVD[2:1]

 

 

 

 

 

 

Pull-up R

50 K

 

.3.6

 

Notes: 1) Control Signals: each card shall present a load to the socket no larger than 50 pF 10 at a DC current of 700 A

 

 

 

 

 

 

 

 

 

 

 

Ω

 

 

low state and 150 A high state, including pull-resistor. The socket shall be able to drive at least the following load 10 while meeting all AC timing requirements: (the number of sockets wired in parallel) multiplied by (50 pF

with DC current 700

 

A low state and 150 A high state per socket).

AΩlow

2) Resistor is optional.

 

 

 

3) Status Signals: the socket shall present a load to the card no larger than 50 pF 10 at a DC currentΩ ≦ of400

Transcend Information Inc.μ

μ

μ

17

μ μ V1.0