TS8G~16GCF600 | 600X CompactFlash Card | |
|
|
|
Notes: 1) The parameters tUI, tMLI : (Ultra DMA
2)
3)Timing for tDVS, tDVH, tCVS and tCVH shall be met for lumped capacitive loads of 15 and 40 pF at the connector where the Data and STROBE signals have the same capacitive load value. Due to reflections on the cable, these timing measurements are not valid in a normally functioning system. 4)For all modes the parameter tZIORDY may be greater than tENV due to the fact that the host has a
5)The parameters tDS, and tDH for mode 5 are defined for a recipient at the end of the cable only in a configuration with a single device located at the end of the cable. This could result in the minimum values for tDS and tDH for mode 5 at the middle connector being 3.0 and 3.9 ns respectively.
| UDMA |
| UDMA |
| UDMA |
| UDMA |
| UDMA | UDMA | UDMA | |||||||
Name | Mode 0 |
| Mode 1 |
| Mode 2 |
| Mode 3 |
| Mode4 | Mode 5 | Mode 6 | |||||||
| (ns) |
| (ns) |
| (ns) |
| (ns) |
| (ns) | (ns) | (ns) | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Min |
| Max | Min |
| Max | Min |
| Max | Min |
| Max | Min | Max | Min | Max | Min | Max |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
tDSIC | 14.7 |
|
| 9.7 |
|
| 6.8 |
|
| 6.8 |
|
| 4.8 |
| 2.3 |
| 2.3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
tDHIC | 4.8 |
|
| 4.8 |
|
| 4.8 |
|
| 4.8 |
|
| 4.8 |
| 2.8 |
| 2.8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
tDVSIC | 72.9 |
|
| 50.9 |
|
| 33.9 |
|
| 22.6 |
|
| 9.5 |
| 6.0 |
| 5.2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
tDVHIC | 9.0 |
|
| 9.0 |
|
| 9.0 |
|
| 9.0 |
|
| 9.0 |
| 6.0 |
| 5.2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
tDSIC | Recipient IC data setup time (from data valid until STROBE edge) (see note 2) |
|
|
|
| |||||||||||||
|
|
|
| |||||||||||||||
tDHIC | Recipient IC data hold time (from STROBE edge until data may become invalid) (see note 2) |
|
|
tDVSIC
Sender IC data valid setup time (from data valid until STROBE edge) (see note 3)
tDVHIC
Sender IC data valid hold time (from STROBE edge until data may become invalid) (see note 3)
Notes: 1) All timing measurement switching points(low to high and high to low) shall be taken at 1.5 V.
2)The correct data value shall be captured by the recipient given input data with a slew rate of 0.4 V/ns rising and falling and the input STROBE with a slew rate of 0.4 V/ns rising and falling at tDSIC and tDHIC timing (as measured through 1.5 V).
3)The parameters tDVSIC and tDVHIC shall be met for lumped capacitive loads of 15 and 40 pF at the IC where all signals have the same capacitive load value. Noise that may couple onto the output signals from external sources has not been included in these values.
Transcend Information Inc. | 35 |