Tripp Lite 108, 116 manual To input the DDC information

Models: 116 108

1 45
Download 45 pages 9.88 Kb
Page 26
Image 26
To input the DDC information:

SMART CAT5 SWITCH – 108/116

Input the DDC information of the monitor connected to the Smart CAT5 switch into the memories of all connected ROC/RICCs when first installing system.

To input the DDC information:

1.Disconnect the Video cable of all ROC/RICCs from the computers.

2.Press Shift twice to open the OSD.

3.Press F10. “Please wait” flashes a few times and disappears. The monitor’s DDC information is sent to all ROC/RICCs.

4.Reconnect the Video cable of all ROC/RICCs.

4.2.14.1 Updating the DDC information

Update the DDC information in any of the following circumstances:

When replacing the monitor connected to Smart CAT5 Switch

When adding a new ROC/RICC to the system

When reconnecting an existing ROC/RICC that was temporarily used in a different system

To update the DDC information, repeat the steps as set out above.