Care and Cleaning

(continued)

 

 

4. Remove dirt on the fan filter using a vacuum

cleaner or other cleaning equipment.

Hold the sponge with your hand so that it is not sucked into the cleaner.

If the sponge is removed, attach it again as shown below.

Side filterBottom filter

Press down the sponge intoPlace the sponge the dents at four corners, and

Cleaning the card feed rollers and heat

rollers

Dirty rollers are the major cause of jamming of the cards. It is recommended to clean the rollers once after printing about 1,000 cards. It is also recommended to carry out cleaning before the work, because the retransfer roller (heat roller) does not operate while it is hot.

1. Remove the retransfer film cassette.

See p.16 in this manual.

2. Turn on the power of the printer.

The printer initializes, and the [No Cassette] error is indicated.

3. From user mode select cleaning mode.

> U s e r M o d e

MENU

> C l e a n i n g >

set it under the tabs on the

under the tabs on the

frame.

frame.

4.

Press the ENTER button. Select [Rollers] with

 

and buttons, and press the ENTER button.

 

 

 

See p.31 in this manual.

 

 

 

> > R o l l e r s

 

 

 

 

 

O K ?

 

 

 

 

 

 

 

 

 

ENTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C l e a n i n g . .

S t a r t O K ?

Replace the fan filter when it begins to deteriorate.(the elasticity of the sponge is lost and the sponge tends to be broken into pieces.) It is recommended that fan filter should be replaced once a year. Contact your dealer for details of replacing the filter.

5.Install the fan filters back to the original positions.

ENTER

C l e a n i n g . .

Insert the cleaning card in about 10 seconds. If you fails to set the card within this time, the printer returns to “Start OK?” Press the ENTER button again to proceed.

42

Page 42
Image 42
Ultra electronic Prima 3 user manual Cleaning the card feed rollers and heat Rollers, See p.31 in this manual