Uniden BC296D manual Reverse List

Models: BC296D

1 88
Download 88 pages 46.74 Kb
Page 82
Image 82

Event Code

Standard

Event Level (Siren Type)

 

LCD Display

 

 

 

 

 

 

Warning

Watch

Statement

Test

 

Severe Weather Statement

SVS

 

 

0

 

SEVERE WX

Special Weather Statement

SPS

 

 

0

 

SPECIAL WX

Flash Flood Statement

FFS

 

 

0

 

FLASH FLOOD

Flood Statement

FLS

 

 

0

 

FLOOD

Hurricane Statement

HLS

 

 

0

 

HURRICANE

National Periodic Test

NPT

 

 

 

0

NATION PERIOD

Required Monthly Test

RMT

 

 

 

0

MONTHLY

Required Weekly Test

RWT

 

 

 

0

WEEKLY

System Demonstration/ Practice

DMO

 

 

 

Note

SYSTEM DEMO

National Hazard Warning

NHW

0

 

 

 

NATION HAZARD

Unknown Emergency Tune TV

**E

0

 

 

 

UNKNOWN TV

Unknown Warning Tune TV

**W

0

 

 

 

UNKNOWN TV

Unknown Watch Tune TV

**A

 

0

 

 

UNKNOWN TV

Unknown Statement Tune TV

**S

 

 

0

 

UNKNOWN TV

Administrative Message

ADR

 

 

0

 

ADMIN MESSAGE

Child Abduction Emergency

CAE

0

 

 

 

CHILD EMERGENCY

Dusd Storm Warning

DSW

0

 

 

 

DUST STORM

Earthquake Warning

EQW

0

 

 

 

EARTHQUAKE

Network Message Notification

NMN

 

 

0

 

NETWORK MESSAGE

911 telephone Outage Emergency

TOE

0

 

 

 

911 PHONE OUTAGE

Nuclear Power Plant Warning

NUW

0

 

 

 

NUCLEAR PLANT

Tropical Storm Warning

TRW

0

 

 

 

TROPICAL STORM

Tropical Storm Watch

TRA

 

0

 

 

TROPICAL STORM

Dust Storm Watch

DSA

 

0

 

 

DUST STORM

Earthquake Watch

EQA

 

0

 

 

EATHQUAKE

Missing Child Statement

MIS

 

 

0

 

MISSING CHILD

Nuclear Power Plant Test Messag

NPM

 

 

 

0

NUCLEAR PLANT

Nuclear Power Plant Warning

NPW

0

 

 

 

NUCLEAR PLANT

Nuclear Power Plant Warning

NPP

0

 

 

 

NUCLEAR PLANT

School Closing Statement

SCS

 

 

0

 

SCHOOL CLOSING

Dam Break Warning

DBW

0

 

 

 

DAM BREAK

Note: Demo alerts are displayed but no audible alert is generated.

REVERSE LIST

Range

Offset

Range

Offset

29.520

- 29.580

+0.1 MHz

445.000 - 449.9875

-5 MHz

29.620

- 29.680

-0.1 MHz

450.000 - 454.9875

+5 MHz

52.010

- 52.990

+1 MHz

455.000 - 459.9875

-5 MHz

53.010

- 53.990

-1 MHz

460.000 - 464.9875

+5 MHz

143.750

+4.375 MHz

465.000 - 469.9875

-5 MHz

143.900

+4.25 MHz

470.000 - 472.9875

+3 MHz

144.510

- 144.890

+0.6 MHz

473.000 - 475.9875

-3 MHz

145.110

- 145.490

-0.6 MHz

476.000 - 478.9875

+3 MHz

146.010

- 146.385

+0.6 MHz

479.000 - 481.9875

-3 MHz

146.415

- 146.505

+1 MHz

482.000 - 484.9875

+3 MHz

146.595

+1 MHz

485.000 - 487.9875

-3 MHz

146.610

- 146.985

-0.6 MHz

488.000 - 490.9875

+3 MHz

147.000

- 147.390

+0.6 MHz

491.000 - 493.9875

-3 MHz

147.415

- 147.505

-1 MHz

494.000 - 496.9875

+3 MHz

147.595

-1 MHz

497.000 - 499.9875

-3 MHz

147.600

- 147.990

-0.6 MHz

500.000 - 502.9875

+3 MHz

148.125

-4.375 MHz

503.000 - 505.9875

-3 MHz

148.150

-4.25 MHz

506.000 - 508.9875

+3 MHz

222.120

- 223.380

+1.6 MHz

509.000 - 511.9875

-3 MHz

223.720

- 224.980

-1.6 MHz

806.000 - 823.9875

+45 MHz

420.000 - 424.9875

+5 MHz

851.000 - 868.9875

-45 MHz

425.000 - 429.9875

-5 MHz

896.000 - 901.000

+39 MHz

440.000 - 444.9875

+5 MHz

935.000 - 940.000

-39 MHz

The reverse frequency for trunked systems is determined by the trunking system settings and can vary from the standard band plans.

76

Page 82
Image 82