Technical Information

Frequency Bands And Steps

The followingtable shows the 16 bands you can monitorwithyour scanner. The signal modes and the steps are default settings that you can override. See "Settingthe Signal Mode"on Page 36, and "Changingthe Frequency Step" on Page 35.

Frequency

Signal

Default

Coverage

(MHz)

Mode

Steps (kHz)

25.0000

to

28.9950

AM

5.0

29.0000

to

55.9950

NFM

5.0

56.0000

to

69.9500

WFM

50.0

70.0000

to

87.9950

NFM

5.0

88.0000

to 107.9500

WFM

50.0

108.0000

to 136.9875

AM

12.5

137.0000

to 173.9950

NFM

5.0

174.0000

to 221.9500

WFM

50.0

222.0000

to 399.9875

AM

12.5

400.0000

to 519.9875

NFM

12.5

520.0000

to 549.9500

WFM

50.0

760.0000

to 823.9875

NFM

12.5

Frequency Signal Default

Coverage (MHz) Mode Steps (kHz)

824.0100 to 848.9700 NFM 30.0

849.0000 to 868.9875 NFM 12.5

869.0100 to 893.9700 NFM 30.0

894.0000 to 1300.0000 NFM 12.5

42

- -- ~--

Page 46
Image 46
Uniden UBC3000XLT manual Technical Information