Vanguard Managed Solutions 650 Data 1 and Data 2 Cable Descriptions, Cable Pinout, Pin #, Itu-T

Models: 650

1 82
Download 82 pages 61.12 Kb
Page 66
Image 66
Data 1 and Data 2 Cable Descriptions

Data 1 and Data 2 Cable Descriptions

Data 1 and Data 2 Cable Descriptions

Introduction

Each Vanguard 650 Series product has two Data connectors located at the rear of the

 

unit. One of these connectors, labeled Data 1, is an RJ45, and the other connector,

 

labeled Data 2, is a DB25 female.

Data 1 (RJ45) Port The connector pins of the Data 1 port are numbered from left to right as indicated in

Cable Pinout

the following diagram:

 

Pin 1

 

 

 

 

 

Pin 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data 1 (RJ45) Port For the 651/653 product, this port can be used to connect an EIA-232 device, using

EIA-232 Cable the following pinout for the RJ45 jack:

Pinout

 

Interface Signal Name

 

 

 

Pin #

EIA

ITU-T V.24

 

 

 

1

TxD

103

 

 

 

2

Signal Ground

102

 

 

 

3

TxC

114

 

 

 

4

RTS

105

 

 

 

5

RxC

115

 

 

 

6

DTR

108

 

 

 

7

RxD

104

 

 

 

8

CTS

106

 

 

 

Cable PinoutPinout Note

You can use the DB25 to RJ45 cable (part number 68361) to access the sync port.