Step 1

Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size. (Fig. 32) (For combustible walls first frame in opening.)

NOTE: When using flex vent, the opening will have to be measured according to the 1/2” (13 mm) rise in 12” (305 mm) vent run.

Combustible Walls: Cut a 9³⁄”H x 9³⁄”W (240 mm x 240 mm) hole through the exterior wall and frame as shown. (Fig. 32)

Noncombustible Walls: Hole opening must be 7¹⁄” (191mm) in diameter.

Vent Opening for Combustible Walls

Adjustable Zero

Max. Length

Clearance Sleeve

12” (305 mm)

 

 

#8 Screws (2)

#8 Screws

 

(2)

 

 

#8 Screws

 

(2)

Firestop

Adjustable Zero

 

Clearance Sleeve

ZCS101

Fig. 33 Adjustable zero clearance sleeve.

 

9³⁄

(240 mm)

9³⁄

(240 mm)

Fireplace Hearth

Framing Detail

FP1181

Fig. 34 Vertical height requirements.

Step 4

Opening for Noncombustible Wall

7¹⁄

(190 mm)

Fireplace Hearth

VO584-100

Fig. 32 Locate vent opening on wall.

Step 2

Measure wall thickness and cut zero clearance sleeve parts to proper length (MAXIMUM 12” / 305 mm). Assemble sleeve and attach to firestop with #8 sheet metal screws (supplied). Install firestop assembly. (Fig. 33)

Zero clearance sleeve is only required for combustible walls.

Step 3

Place fireplace into position. Measure the vertical height

(X)required from the base of the flue collars to the cen- ter of the wall opening. (Fig. 34)

Apply a band of silicone to the inner and outer flue collars of the fireplace and using appropriate length of pipe section(s) attach to fireplace with three (3) screws. Follow with the installation of the inner and outer elbow, again secure joints with three (3) sheet metal screws. Wipe off any excess high temperature sealant.

Step 5

Measure the horizontal length requirement including a 2” (51mm) overlap, i.e. from the elbow to the outside wall face plus 2” (51mm) (or the distance required if installing a second 90° elbow). (Fig. 35)

Always install horizontal venting on a level plane.

Step 6

Use appropriate length of pipe sections - telescopic or fixed - and install. The sections which go through the wall are packaged with the starter kit, and can be cut to suit if necessary.

Sealing vent pipe and firestop gaps with high tem- perature sealant will restrict cold air being drawn in around fireplace.

18

20010667

Page 18
Image 18
Vermont Casting DV360 Vertical Sidewall Installation Twist Lock Pipe, Always install horizontal venting on a level plane

DV580, DV360, DV360 specifications

Vermont Castings is a name synonymous with quality and craftsmanship in the world of fireplaces. Among their celebrated products, the DV580, DV360, and DV360 stand out for their advanced technology, efficiency, and aesthetic appeal. Each of these models offers unique features designed to enhance home heating while maintaining a focus on environmental responsibility.

The DV580 is a powerful direct vent gas stove that seamlessly combines traditional aesthetics with modern functionality. With its large viewing window, it creates a cozy ambiance while allowing users to enjoy the mesmerizing flames. One of its main features is the advanced burner system, which provides a realistic flame appearance. This model also boasts an impressive BTU output, allowing it to heat larger spaces efficiently. The unit is equipped with an electronic ignition, ensuring reliable start-ups even in cold weather.

The DV360, a slightly smaller but equally efficient model, offers versatility for various home settings. With its compact design, it can fit into tighter spaces without sacrificing heating capacity. The DV360 features a unique dual burner system, which promotes a more even and consistent flame. Its direct vent technology ensures that all combustion byproducts are vented outside, maintaining indoor air quality. This model also includes an adjustable flame height, giving users control over the intensity of the heat and ambiance.

In addition to performance, both the DV580 and DV360 prioritize energy efficiency. They are designed to operate with minimal emissions, making them an environmentally friendly choice for homeowners. With a variety of finish options and customizable face designs, these models can complement any home decor. Another key characteristic is the straightforward installation process, which allows homeowners the benefit of having their unit up and running in no time.

Overall, the Vermont Castings DV580, DV360, and DV360 models exemplify a harmonious blend of innovation, functionality, and style. They not only provide warmth but also contribute to the overall aesthetic of any space. With their commitment to quality and performance, Vermont Castings continues to set the standard for direct vent gas stoves, ensuring customers enjoy the best of both worlds: comfort and beauty in their homes.