Vermont Casting DV580, DV360 Framing And Finishing, Final Finishing, Gas Specifications, 20010667

Models: DV580, DV360 DV360

1 56
Download 56 pages 36.98 Kb
Page 7
Image 7
Framing And Finishing

Framing And Finishing

Check fireplace to make sure it is levelled and properly positioned.

To mount the appliance: Choose the location. DV360 (Fig. 5)

1.This unit comes with four (4) flanges pre-mounted on both sides of the fireplace to allow two different drywall thicknesses to be used. Flange “A” is for 1/2” drywall while flange “B“ is for 5/8” drywall.

2.Bend the desired flanges out 90° on both sides of the fireplace. Slide the fireplace into the framed opening until the flanges contact the front surfaces of the framing. Level the unit and secure it firmly in place.

Flange

Drywall

Flange Location for

Position

Depth

Desired Drywall Depth

A

1/2” / 13 mm

 

B

5/8” / 16 mm

 

A B

FP1539

Fig. 5 Drywall flange location for DV360.

DV580 (Fig. 5a)

1.Nailing flanges are supplied with the fireplace (found on the fireplace hearth). To level the box and secure it firmly in place, remove the nailing flanges from the hearth and install at the sides of the fireplace as shown in Figure 5a.

2.Screw through the slotted holes in the drywall strip and into pre-drilled holes in fireplace side. Measure from face of fireplace to the face of the drywall strip to confirm the final depth.

Final Finishing

Noncombustible materials such as brick or tile can be extended over the edges of the face of the fireplace.

Do not cover the window frame assembly, any vent, louvre assembly top or louvre assembly bottom. If a Trim Kit is to be installed, brick and tile will have to be installed flush with the side of this appliance.

DV360/580 Series Direct Vent Gas Fireplace

C

Adjustable Drywall Strip

A

(Nailing Flange)

 

 

B

 

 

 

Flange

Drywall

 

Position

Depth

 

A

1/2” / 13 mm

 

B

5/8” / 16 mm

 

C

3/4” / 19 mm

 

Adjustable

 

1/2”, 5/8” & 3/4”

 

Spacing

 

 

FP1023

Fig. 5a Adjustable drywall strip (nailing flange) for DV580.

DV360 / DV580

Certified To

ANSI Z21.88-2005 / CSA 2.33-2005

Vented Gas Fireplace Heater

For units:

GFDN4L2, GFDE4L2, GFDI4L2, GFDL4L2 GFDN4P0, GFDE4P0, GFDI4P0

Gas Specifications

 

 

 

MAX.

 

MIN.

 

 

 

 

 

 

GAS

INPUT

 

INPUT

MODEL

FUEL

CONTROL

B.T.U.H

 

B.T.U.H.

DV360RN

Natural Gas

Millivolt Hi/Lo

30,000

 

18,500

DV360RP

Propane

Millivolt Hi/Lo

30,000

 

17,000

DV360EN

Natural Gas

24 Volt Hi/Lo

30,000

 

18,500

DV360EP

Propane

24 Volt Hi/Lo

30,000

 

20,000

DV360RFN

Natural Gas

Comfort Control

30,000

 

20,000

DV360RFP

Propane

Comfort Control

30,000

 

21,000

DV580RN

Natural Gas

Millivolt Hi/Lo

38,000

 

26,500

DV580RP

Propane

Millivolt Hi/Lo

38,000

 

27,000

DV580EN

Natural Gas

24 Volt Hi/Lo

38,000

 

26,500

DV580EP

Propane

24 Volt Hi/Lo

38,000

 

27,000

DV580RFN

Natural Gas

Comfort Control

38,000

 

26,500

DV580RFP

Propane

Comfort Control

38,000

 

27,000

Gas Inlet and Manifold Pressures

 

Natural

LP (Propane)

Minimum Inlet Pressure

5.5” w.c.

11.0” w.c.

Maximum Inlet Pressure

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

 

 

 

20010667