Framing And Finishing
Check fireplace to make sure it is levelled and properly positioned.
To mount the appliance: Choose the location. DV360 (Fig. 5)
1.This unit comes with four (4) flanges
2.Bend the desired flanges out 90° on both sides of the fireplace. Slide the fireplace into the framed opening until the flanges contact the front surfaces of the framing. Level the unit and secure it firmly in place.
Flange | Drywall | Flange Location for |
Position | Depth | Desired Drywall Depth |
A | 1/2” / 13 mm |
|
B | 5/8” / 16 mm |
|
A B
FP1539
Fig. 5 Drywall flange location for DV360.
DV580 (Fig. 5a)
1.Nailing flanges are supplied with the fireplace (found on the fireplace hearth). To level the box and secure it firmly in place, remove the nailing flanges from the hearth and install at the sides of the fireplace as shown in Figure 5a.
2.Screw through the slotted holes in the drywall strip and into
Final Finishing
Noncombustible materials such as brick or tile can be extended over the edges of the face of the fireplace.
Do not cover the window frame assembly, any vent, louvre assembly top or louvre assembly bottom. If a Trim Kit is to be installed, brick and tile will have to be installed flush with the side of this appliance.
DV360/580 Series Direct Vent Gas Fireplace
C | Adjustable Drywall Strip | |
A | (Nailing Flange) | |
|
| |
B |
|
|
| Flange | Drywall |
| Position | Depth |
| A | 1/2” / 13 mm |
| B | 5/8” / 16 mm |
| C | 3/4” / 19 mm |
| Adjustable | |
| 1/2”, 5/8” & 3/4” | |
| Spacing | |
|
| FP1023 |
Fig. 5a Adjustable drywall strip (nailing flange) for DV580. |
DV360 / DV580
Certified To
ANSI
Vented Gas Fireplace Heater
For units:
GFDN4L2, GFDE4L2, GFDI4L2, GFDL4L2 GFDN4P0, GFDE4P0, GFDI4P0
Gas Specifications
|
|
| MAX. |
| MIN. |
|
|
|
| ||
|
| GAS | INPUT |
| INPUT |
MODEL | FUEL | CONTROL | B.T.U.H |
| B.T.U.H. |
DV360RN | Natural Gas | Millivolt Hi/Lo | 30,000 |
| 18,500 |
DV360RP | Propane | Millivolt Hi/Lo | 30,000 |
| 17,000 |
DV360EN | Natural Gas | 24 Volt Hi/Lo | 30,000 |
| 18,500 |
DV360EP | Propane | 24 Volt Hi/Lo | 30,000 |
| 20,000 |
DV360RFN | Natural Gas | Comfort Control | 30,000 |
| 20,000 |
DV360RFP | Propane | Comfort Control | 30,000 |
| 21,000 |
DV580RN | Natural Gas | Millivolt Hi/Lo | 38,000 |
| 26,500 |
DV580RP | Propane | Millivolt Hi/Lo | 38,000 |
| 27,000 |
DV580EN | Natural Gas | 24 Volt Hi/Lo | 38,000 |
| 26,500 |
DV580EP | Propane | 24 Volt Hi/Lo | 38,000 |
| 27,000 |
DV580RFN | Natural Gas | Comfort Control | 38,000 |
| 26,500 |
DV580RFP | Propane | Comfort Control | 38,000 |
| 27,000 |
Gas Inlet and Manifold Pressures
| Natural | LP (Propane) |
Minimum Inlet Pressure | 5.5” w.c. | 11.0” w.c. |
Maximum Inlet Pressure | 14.0” w.c. | 14.0” w.c. |
Manifold Pressure | 3.5” w.c. | 10.0” w.c. |
|
|
|
20010667 | 7 |