DV360/580 Series Direct Vent Gas Fireplace
Shutter | Burner Pan |
|
|
| |
Retaining |
| |
Screw |
|
|
Air |
|
|
Shutter |
| |
| Front View | CO103 |
Fig. 71 | Remove air shutter from burner pan. |
|
6.
Pilot Orifice Conversion
NOTE: It is not necessary to remove the pilot tube for conversion.
1.Remove pilot hood by lifting up. (Fig. 72)
2.Remove pilot orifice with Allen wrench. (Fig. 73)
3.Install conversion pilot orifice.
4.
Pilot Hood |
Pilot |
Bracket |
moval Section” Page 24, Fig. 47)
2.Remove logs if previously installed. CAUTION: Logs may be hot!
3.Remove and replace plug on lower right hand side of the valve; Red for LP and blue for NG. (Fig. 74)
4.Remove motor top cap. Depress and turn center plunger until arrow points to correct screw. Red for LP and Blue for NG. NOTE: Plunger will “snap” into NG position when arrow is close to blue screw. It will not “snap” at LP (Red) position. (Fig. 75)
| Motor Top Cap |
|
| Piezo Ignitor |
| |
|
|
|
|
| T |
|
|
|
|
| O |
| |
|
|
| IL |
|
| |
|
|
| P |
| OFF |
|
|
|
|
|
| • |
|
|
|
| N |
|
|
|
|
|
| O• |
|
|
|
| LOCAL | REMOTE |
|
| LED |
|
|
|
|
|
| ||
|
|
|
| LED |
| |
Local/ |
| Pilotstat |
|
| Plug |
|
Remote Switch | Knob |
|
|
| ||
|
| Antenna |
| |||
|
|
|
|
| FP1037 | |
|
|
|
|
|
| |
Fig. 74 | Comfort control valve. |
|
|
|
|
CO105a |
Fig. 72 Remove pilot hood. |
Index Tab | Allen Wrench |
Center
Plunger
Blue - NG Red - LP
Motor Top Cap
LOCAL
FP1037b
Snap Ring |
CO106a |
Fig. 73 Remove pilot orifice. |
Fuel Conversion Instructions
Honeywell Comfort Control Valve ONLY
WARNING: The conversion must only be undertaken by a qualified, certified gas ap- pliance installer.
Installation Precautions
Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance. CAUTION: Logs may be hot!
Conversion Procedure
1.Open bottom grille to gain access to valve. Remove glass door. (Refer to “Window Frame Assembly Re-
Fig. 75 Depress and turn center plunger.
Burner Orifice Conversion
DV360
1.Remove the screws that secure the fettle and the burner tube assembly, located behind the burner tube assembly. Remove the two (2) screws that secure the burner housing assembly to the base pan at the right end of the burner housing assembly. (Fig. 66)
2.Remove the fettle and the burner tube assembly. Slide the burner housing assembly to the right and up to free the orifice.
3.Using a 1/2” open end wrench remove the orifices. (Fig. 67)
4.Converting LP to NG, remove bracket/gasket as- sembly by unfastening the screw which secures the bracket to the burner tray base. Discard bracket and refasten the screw into the hole. (Fig. 67a)
Converting NG to LP, assemble the bracket/gas- ket assembly to the burner tray assembly base by
42 | 20010667 |