Vermont Casting DV360 Fuel Conversion Instructions Honeywell Comfort Control Valve ONLY, 20010667

Models: DV580, DV360 DV360

1 56
Download 56 pages 36.98 Kb
Page 42
Image 42
Front View

DV360/580 Series Direct Vent Gas Fireplace

Shutter

Burner Pan

 

 

 

Retaining

 

Screw

 

 

Air

 

 

Shutter

 

 

Front View

CO103

Fig. 71

Remove air shutter from burner pan.

 

6. Re-install manifold to burner pan.

Pilot Orifice Conversion

NOTE: It is not necessary to remove the pilot tube for conversion.

1.Remove pilot hood by lifting up. (Fig. 72)

2.Remove pilot orifice with Allen wrench. (Fig. 73)

3.Install conversion pilot orifice.

4.Re-install pilot hood and be sure to align with index tab. Installation is complete.

Pilot Hood

Pilot

Bracket

moval Section” Page 24, Fig. 47)

2.Remove logs if previously installed. CAUTION: Logs may be hot!

3.Remove and replace plug on lower right hand side of the valve; Red for LP and blue for NG. (Fig. 74)

4.Remove motor top cap. Depress and turn center plunger until arrow points to correct screw. Red for LP and Blue for NG. NOTE: Plunger will “snap” into NG position when arrow is close to blue screw. It will not “snap” at LP (Red) position. (Fig. 75)

 

Motor Top Cap

 

 

Piezo Ignitor

 

 

 

 

 

 

T

 

 

 

 

 

O

 

 

 

 

IL

 

 

 

 

 

P

 

OFF

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

O•

 

 

 

 

LOCAL

REMOTE

 

 

LED

 

 

 

 

 

 

 

 

 

 

LED

 

Local/

 

Pilotstat

 

 

Plug

 

Remote Switch

Knob

 

 

 

 

 

Antenna

 

 

 

 

 

 

FP1037

 

 

 

 

 

 

Fig. 74

Comfort control valve.

 

 

 

 

CO105a

Fig. 72 Remove pilot hood.

Index Tab

Allen Wrench

Center

Plunger

Blue - NG Fuel Conversion InstructionsManual background Red - LP

Motor Top Cap

LOCALManual background

FP1037b

Snap Ring

CO106a

Fig. 73 Remove pilot orifice.

Fuel Conversion Instructions

Honeywell Comfort Control Valve ONLY

WARNING: The conversion must only be undertaken by a qualified, certified gas ap- pliance installer.

Installation Precautions

Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance. CAUTION: Logs may be hot!

Conversion Procedure

1.Open bottom grille to gain access to valve. Remove glass door. (Refer to “Window Frame Assembly Re-

Fig. 75 Depress and turn center plunger.

Burner Orifice Conversion

DV360

1.Remove the screws that secure the fettle and the burner tube assembly, located behind the burner tube assembly. Remove the two (2) screws that secure the burner housing assembly to the base pan at the right end of the burner housing assembly. (Fig. 66)

2.Remove the fettle and the burner tube assembly. Slide the burner housing assembly to the right and up to free the orifice.

3.Using a 1/2” open end wrench remove the orifices. (Fig. 67)

4.Converting LP to NG, remove bracket/gasket as- sembly by unfastening the screw which secures the bracket to the burner tray base. Discard bracket and refasten the screw into the hole. (Fig. 67a)

Converting NG to LP, assemble the bracket/gas- ket assembly to the burner tray assembly base by

42