Vermont Casting DV360/580 Series Direct Vent Gas Fireplace, Auto Path, LED Count, 20010667

Models: DV580, DV360 DV360

1 56
Download 56 pages 36.98 Kb
Page 34
Image 34
LED Count

DV360/580 Series Direct Vent Gas Fireplace

LED Count

Service Action

8Replace valve

7Confirm stepper motor connection exists

5Confirm fan connection exists and works

4Confirm gas type; jumper in place

3Replace thermopiles

2Turn fan ON NOTE: Some keys are not active.

Auto Path

If the manual switch is

 

 

set to REMOTE, press

 

 

 

Move switch

the mode button to

 

 

from LOCAL to

display AUTO on the

 

 

REMOTE. Press

transmitter. Does the

 

 

any key within 30

transmitter display the

 

 

seconds.

room and temperature

 

 

 

setting?

 

 

Yes

If the setting is above room temperature on the transmitter, does the main valve and fan turn on?

No

Yes

If the setting is below room temperature on the transmitter, does the main valve and fan turn off?

Turn pilotstat knob to OFF to turn valve completely off

No

34

20010667

Page 34
Image 34
Vermont Casting manual DV360/580 Series Direct Vent Gas Fireplace, Auto Path, LED Count, Service Action, 20010667